Separation of dilute plutonium(IV) from nitric acid solutions via Reillex HPQ anion exchange resin

Anion exchange is a common method for the separation of plutonium (Pu) in aqueous systems, providing high recovery and decontamination from impurities. Reillex HPQ anion exchange resin has been used around the Department of Energy complex in this application for decades but has typically been used for Pu feed concentrations greater than 1 g/L. It is desirable to recover Pu at more dilute concentrations from a dissolved used fuel or target element, for example. In this work, the performance of Reillex HPQ anion exchange resin was characterized with feed solutions of ca. 0.24 g/L Pu. A significant reduction in the performance of the resin was realized with this dilute concentration relative to a feed solution of 2.35 g/L Pu with similar feed flow rates and the same resin column, likely due to the increased driving force for mass transfer with a higher feed concentration. The maximum capacity of Reillex HPQ resin for Pu can be improved by reducing the flow rate and increasing the feed Pu concentration. The breakthrough point of Pu can be improved in the same manner and by increasing the resin bed height. Diffusion of Pu into the resin was illustrated to be the rate limiting step.

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.29333258.v1
Primary Topic
Radioactive element chemistry and processing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Separation of dilute plutonium(IV) from nitric acid solutions via Reillex HPQ anion exchange resin

Figshare
Radioactive element chemistry and processing
article

Separation of dilute plutonium(IV) from nitric acid solutions via Reillex HPQ anion exchange resin

article en

Abstract

Anion exchange is a common method for the separation of plutonium (Pu) in aqueous systems, providing high recovery and decontamination from impurities. Reillex HPQ anion exchange resin has been used around the Department of Energy complex in this application for decades but has typically been used for Pu feed concentrations greater than 1 g/L. It is desirable to recover Pu at more dilute concentrations from a dissolved used fuel or target element, for example. In this work, the performance of Reillex HPQ anion exchange resin was characterized with feed solutions of ca. 0.24 g/L Pu. A significant reduction in the performance of the resin was realized with this dilute concentration relative to a feed solution of 2.35 g/L Pu with similar feed flow rates and the same resin column, likely due to the increased driving force for mass transfer with a higher feed concentration. The maximum capacity of Reillex HPQ resin for Pu can be improved by reducing the flow rate and increasing the feed Pu concentration. The breakthrough point of Pu can be improved in the same manner and by increasing the resin bed height. Diffusion of Pu into the resin was illustrated to be the rate limiting step.

Figshare
Affordable and clean energy
Openalex Percentile: Top 64%
Radioactive element chemistry and processing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.