A rapid and sensitive UHPLC-MS/MS method for epalrestat detection in micro-volumes of human plasma for the first time

A rapid and sensitive ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for epalrestat detection in human plasma. A triple quadrupole tandem mass spectrometer equipped with an electrospray ionization (ESI) source was used to quantify epalrestat and the internal standard epalrestat-d<sub>5</sub> in the negative ion mode using multiple reaction monitoring (MRM). After acetonitrile-mediated protein precipitation, chromatographic separation was achieved using a reversed-phase C<sub>18</sub> column (ACQUITY UPLC BEH, 2.1 × 50 mm, 1.7 μm; Waters Corp) with acetonitrile and 2 mM ammonium acetate in water as the mobile phase through gradient elution. The retention time of epalrestat was 0.92 min and the entire run time was only 2.00 min. The calibration curve was linear in the range 10.0–8.00 × 10<sup>3</sup> ng/mL (<i>r</i> ≥ 0.99). The within-run and between-run relative standard deviations (RSDs) were &lt; 9.3%. The within-run and between-run relative errors (REs) ranged −8.4–4.2%. No significant matrix effects were observed and the recovery rate was high. The method was fully validated, including reinjection reproducibility in human plasma, and was successfully applied in a pharmacokinetic study, in which 100% incurred sample reanalysis met the criteria.

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.29152671.v1
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A rapid and sensitive UHPLC-MS/MS method for epalrestat detection in micro-volumes of human plasma for the first time

Figshare
Analytical Methods in Pharmaceuticals
article

A rapid and sensitive UHPLC-MS/MS method for epalrestat detection in micro-volumes of human plasma for the first time

article en

Abstract

A rapid and sensitive ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for epalrestat detection in human plasma. A triple quadrupole tandem mass spectrometer equipped with an electrospray ionization (ESI) source was used to quantify epalrestat and the internal standard epalrestat-d<sub>5</sub> in the negative ion mode using multiple reaction monitoring (MRM). After acetonitrile-mediated protein precipitation, chromatographic separation was achieved using a reversed-phase C<sub>18</sub> column (ACQUITY UPLC BEH, 2.1 × 50 mm, 1.7 μm; Waters Corp) with acetonitrile and 2 mM ammonium acetate in water as the mobile phase through gradient elution. The retention time of epalrestat was 0.92 min and the entire run time was only 2.00 min. The calibration curve was linear in the range 10.0–8.00 × 10<sup>3</sup> ng/mL (<i>r</i> ≥ 0.99). The within-run and between-run relative standard deviations (RSDs) were &lt; 9.3%. The within-run and between-run relative errors (REs) ranged −8.4–4.2%. No significant matrix effects were observed and the recovery rate was high. The method was fully validated, including reinjection reproducibility in human plasma, and was successfully applied in a pharmacokinetic study, in which 100% incurred sample reanalysis met the criteria.

Figshare
Clean water and sanitation
Openalex Percentile: Top 56%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.