Determination of Cd<sup>2+</sup> and Pb<sup>2+</sup> in seawater using a shipborne detection device

A shipborne detection device has been developed for the detection of heavy metal ions in offshore seawater, utilizing a mercury film electrode. The automatic determination of Cd<sup>2</sup>⁺ and Pb<sup>2</sup>⁺ ions in seawater can be conducted without any manual intervention. Waste solutions are collected in a recycling bag for subsequent treatment, thereby preventing environmental pollution. The accuracy, as well as the stability of the measurements, were thoroughly examined. The relative standard deviation for Pb<sup>2</sup>⁺ was determined to be 7.02% after conducting 10 repeated tests using a standard solution concentration of 5 μg L⁻<sup>1</sup> and the relative standard deviation of Cd<sup>2+</sup> is 2.65%. Linear calibration curves have been established along with detection limits of 0.31 μg L⁻<sup>1</sup> for both Cd<sup>2</sup>⁺ and Pb<sup>2</sup>⁺ ions. Ultimately, this shipborne detection device was successfully employed for the in-situ determination of Cd<sup>2</sup>⁺ and Pb<sup>2</sup>⁺ ions in seawater.

Publication Details

Journal
Figshare
Published
2025-01-01
DOI
https://doi.org/10.6084/m9.figshare.28395638
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Cd2+ and Pb2+ in seawater using a shipborne detection device

Figshare
Electrochemical Analysis and Applications
article

Determination of Cd2+ and Pb2+ in seawater using a shipborne detection device

article en

Abstract

A shipborne detection device has been developed for the detection of heavy metal ions in offshore seawater, utilizing a mercury film electrode. The automatic determination of Cd<sup>2</sup>⁺ and Pb<sup>2</sup>⁺ ions in seawater can be conducted without any manual intervention. Waste solutions are collected in a recycling bag for subsequent treatment, thereby preventing environmental pollution. The accuracy, as well as the stability of the measurements, were thoroughly examined. The relative standard deviation for Pb<sup>2</sup>⁺ was determined to be 7.02% after conducting 10 repeated tests using a standard solution concentration of 5 μg L⁻<sup>1</sup> and the relative standard deviation of Cd<sup>2+</sup> is 2.65%. Linear calibration curves have been established along with detection limits of 0.31 μg L⁻<sup>1</sup> for both Cd<sup>2</sup>⁺ and Pb<sup>2</sup>⁺ ions. Ultimately, this shipborne detection device was successfully employed for the in-situ determination of Cd<sup>2</sup>⁺ and Pb<sup>2</sup>⁺ ions in seawater.

Figshare
Life below water
Openalex Percentile: Top 59%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.