Analytical Methods Development and Validation for Estimation of Fimasartan Potassium Trihydrate

A straightforward, rapid, sensitive, precise, and specific UV spectrophotometric method was developed and validated for the determination of Fimasartan Potassium Trihydrate in active pharmaceutical ingredients. The method employed a double-beam UV spectrophotometer and was evaluated for various parameters, including Linearity, Precision, Repeatability, And Accuracy, in accordance with ICH guidelines. The absorption of Fimasartan Potassium Trihydrate was measured at a maximum wavelength of 265 nm in Methanol as the reference medium. The drug followed Lambert-Beer’s law within a concentration range of 5-25 μg/mL, with a correlation coefficient of 0.998. This proposed method is accurate, precise, reproducible, and suitable for routine analysis of isoniazid in active pharmaceutical ingredients. Fimasartan Potassium Trihydrate UV spectrophotometry.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-08-11
DOI
https://doi.org/10.5281/zenodo.16792604
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Methods Development and Validation for Estimation of Fimasartan Potassium Trihydrate

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

Analytical Methods Development and Validation for Estimation of Fimasartan Potassium Trihydrate

article en

Abstract

A straightforward, rapid, sensitive, precise, and specific UV spectrophotometric method was developed and validated for the determination of Fimasartan Potassium Trihydrate in active pharmaceutical ingredients. The method employed a double-beam UV spectrophotometer and was evaluated for various parameters, including Linearity, Precision, Repeatability, And Accuracy, in accordance with ICH guidelines. The absorption of Fimasartan Potassium Trihydrate was measured at a maximum wavelength of 265 nm in Methanol as the reference medium. The drug followed Lambert-Beer’s law within a concentration range of 5-25 μg/mL, with a correlation coefficient of 0.998. This proposed method is accurate, precise, reproducible, and suitable for routine analysis of isoniazid in active pharmaceutical ingredients. Fimasartan Potassium Trihydrate UV spectrophotometry.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 56%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.