Development And Validation of a Spectrofluorimetric Method for The Estimation of Doxycycline in Bulk and Formulation

A simple, accurate, precise, sensitive and cost-effective spectrofluorimetric method was developed and validated for the estimation of Doxycycline in bulk and formulation. The relative fluorescence intensity of Doxycycline was measured in Distilled Water: Methanol (40:60%v/v) at an excitation wavelength of 354 nm and an emission wavelength of 395nm. Proposed method was found to be linear over the range of 50 to 1000 ng/ml with correlation coefficient 0.9999. Proposed method was validated using different analytical method validation parameters viz. Accuracy, precision, LOD, LOQ, robustness and ruggedness using QC standards as per the ICH guidelines. The percentage recovery was found to be 100.66 ± 0.98% and percentage RSD values were found to be less than 2 for accuracy and precision studies. The detection and quantification limits for the proposed method were found to be 4.120 ng/ml and 9.756 ng/ml, respectively. A simple, accurate, precise, sensitive yet cost-effective spectrofluorimetric method was developed for the estimation of Doxycycline in bulk and formulation. The said spectrofluorimetric method was found to be economic as it comprises water as a solvent.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-04-11
DOI
https://doi.org/10.5281/zenodo.15195965
Primary Topic
Distributed systems and fault tolerance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development And Validation of a Spectrofluorimetric Method for The Estimation of Doxycycline in Bulk and Formulation

Zenodo (CERN European Organization for Nuclear Research)
Distributed systems and fault tolerance
article

Development And Validation of a Spectrofluorimetric Method for The Estimation of Doxycycline in Bulk and Formulation

article en

Abstract

A simple, accurate, precise, sensitive and cost-effective spectrofluorimetric method was developed and validated for the estimation of Doxycycline in bulk and formulation. The relative fluorescence intensity of Doxycycline was measured in Distilled Water: Methanol (40:60%v/v) at an excitation wavelength of 354 nm and an emission wavelength of 395nm. Proposed method was found to be linear over the range of 50 to 1000 ng/ml with correlation coefficient 0.9999. Proposed method was validated using different analytical method validation parameters viz. Accuracy, precision, LOD, LOQ, robustness and ruggedness using QC standards as per the ICH guidelines. The percentage recovery was found to be 100.66 ± 0.98% and percentage RSD values were found to be less than 2 for accuracy and precision studies. The detection and quantification limits for the proposed method were found to be 4.120 ng/ml and 9.756 ng/ml, respectively. A simple, accurate, precise, sensitive yet cost-effective spectrofluorimetric method was developed for the estimation of Doxycycline in bulk and formulation. The said spectrofluorimetric method was found to be economic as it comprises water as a solvent.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 52%
Distributed systems and fault tolerance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.