DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR CARIPRAZINE IN BULK AND PHARMACEUTICAL DOSAGE FORM

A simple, accurate, precise, rapid and specific reverse phase HPLC method has been developed for the estimation of Cariprazine in bulk and pharmaceutical dosage forms. The chromatographic separation was achieved on Agilent Zorbax SB-Aq (250 x 4.6mm, 5µ) column. The mobile phase consisted of Acetonitrile: Buffer (50:50 % v/v) at a flow rate 1.0ml/min with diluent Acetonitrile: Water (50:50). The analyte was monitored using UV at 216nm and run time was kept 10min. The column temperature was adjusted at 30ºC with injection volume 10µl. The retention time of Cariprazine was 3.57 min. Linearity was found to be in concentration range of 80-120µg/ml. Cariprazine was checked for its suitability, specificity and other validation parameters. Results of study were valid statistically and by recovery studies. The method was validated according to the ICH guidelines with relevancy to accuracy, precision, specificity and linearity.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-06-15
DOI
https://doi.org/10.5281/zenodo.15672326
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR CARIPRAZINE IN BULK AND PHARMACEUTICAL DOSAGE FORM

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR CARIPRAZINE IN BULK AND PHARMACEUTICAL DOSAGE FORM

article en

Abstract

A simple, accurate, precise, rapid and specific reverse phase HPLC method has been developed for the estimation of Cariprazine in bulk and pharmaceutical dosage forms. The chromatographic separation was achieved on Agilent Zorbax SB-Aq (250 x 4.6mm, 5µ) column. The mobile phase consisted of Acetonitrile: Buffer (50:50 % v/v) at a flow rate 1.0ml/min with diluent Acetonitrile: Water (50:50). The analyte was monitored using UV at 216nm and run time was kept 10min. The column temperature was adjusted at 30ºC with injection volume 10µl. The retention time of Cariprazine was 3.57 min. Linearity was found to be in concentration range of 80-120µg/ml. Cariprazine was checked for its suitability, specificity and other validation parameters. Results of study were valid statistically and by recovery studies. The method was validated according to the ICH guidelines with relevancy to accuracy, precision, specificity and linearity.

Zenodo (CERN European Organization for Nuclear Research)
Clean water and sanitation
Openalex Percentile: Top 56%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.