Impact of Gas Flaring on Rainwater Quality and Public Health: A Study of Soku Community, Rivers State, Nigeria

This study assessed the rain water quality in a Gas flaring Environment as well as the health implication for Soku community in Rivers State, Nigeria. In-situ measurements and analysis of pH, turbidity, colour, electrical conductivity and temperature were done. Eight sampling points were chosen randomly within the strategic study location and control of 500m to 5000m from gas flare point. The points were designated as A, B, C, D, E, F, G and H. Points A, B, C, D are 500m, 1000m, 2000m and 5000m away from the gas flare point and were chosen to show variations in rainwater quality parameters with respect to distance from flare point. Point D served as control location. Points E, F, G were randomly chosen within 500m to 2000m from flare point to show effects on various roofs. Plastic buckets sterilized by rinsing with tap water, chromic acid, 1:1 Nitric acid and finally with distilled water was used to collect rainwater samples on a stand of about 1.5m to avoid splash water contamination. Soil samples were collected from eight different locations and labeled sample location A, B, C, D, E, F, G, and H. The samples collected were stored in 2 liter plastic bottles properly rinsed and labeled. The samples for calcium, magnesium, sodium, chloride, sulphate, nitrate, hardness, TSS and TDS were preserved at temperature of 40C using the Rubbermaid model FG2A0904MODBL-5 QUART Personal ice chest cooler for a maximum holding time of 24 hours. The samples for heavy metal analysis were preserved by adding 2ml conc. HNO3I-1 solution to the sampling bottle before storing the sample to ensure that all composites were well preserved. Samples were taken the laboratory and analyzed using standard methods. The research combined experimental and descriptive survey designs. The experimental design was used to collect data on physicochemical characteristics of rainwater and field data while the descriptive survey design was used to collect secondary data on meteorological elements and primary data from a well-structured Likert 4-point scale close ended questionnaire instrument. Meteorological Data: Weather conditions for six months was extracted from secondary data spanning over ten years from the Nigeria Meteorological Agency (NIMET). Temperature, wind speed and wind directions of sampling points were obtained using the appropriate instruments. Results showed that in Soku Community the first rain is the most polluted followed by the late rain while the mid rain is least, polluted due to discharge of gases and particulates from the atmosphere via washout, rainout, and dilution. It is therefore recommended that government regulatory agencies should put appropriate measures in place to monitor the quantity of gas emissions into the environment and also set and implement polluter pay principle for polluting industries and facilities.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-07-12
DOI
https://doi.org/10.5281/zenodo.15869964
Primary Topic
Oil, Gas, and Environmental Issues
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Gas Flaring on Rainwater Quality and Public Health: A Study of Soku Community, Rivers State, Nigeria

Zenodo (CERN European Organization for Nuclear Research)
Oil, Gas, and Environmental Issues
article

Impact of Gas Flaring on Rainwater Quality and Public Health: A Study of Soku Community, Rivers State, Nigeria

article en

Abstract

This study assessed the rain water quality in a Gas flaring Environment as well as the health implication for Soku community in Rivers State, Nigeria. In-situ measurements and analysis of pH, turbidity, colour, electrical conductivity and temperature were done. Eight sampling points were chosen randomly within the strategic study location and control of 500m to 5000m from gas flare point. The points were designated as A, B, C, D, E, F, G and H. Points A, B, C, D are 500m, 1000m, 2000m and 5000m away from the gas flare point and were chosen to show variations in rainwater quality parameters with respect to distance from flare point. Point D served as control location. Points E, F, G were randomly chosen within 500m to 2000m from flare point to show effects on various roofs. Plastic buckets sterilized by rinsing with tap water, chromic acid, 1:1 Nitric acid and finally with distilled water was used to collect rainwater samples on a stand of about 1.5m to avoid splash water contamination. Soil samples were collected from eight different locations and labeled sample location A, B, C, D, E, F, G, and H. The samples collected were stored in 2 liter plastic bottles properly rinsed and labeled. The samples for calcium, magnesium, sodium, chloride, sulphate, nitrate, hardness, TSS and TDS were preserved at temperature of 40C using the Rubbermaid model FG2A0904MODBL-5 QUART Personal ice chest cooler for a maximum holding time of 24 hours. The samples for heavy metal analysis were preserved by adding 2ml conc. HNO3I-1 solution to the sampling bottle before storing the sample to ensure that all composites were well preserved. Samples were taken the laboratory and analyzed using standard methods. The research combined experimental and descriptive survey designs. The experimental design was used to collect data on physicochemical characteristics of rainwater and field data while the descriptive survey design was used to collect secondary data on meteorological elements and primary data from a well-structured Likert 4-point scale close ended questionnaire instrument. Meteorological Data: Weather conditions for six months was extracted from secondary data spanning over ten years from the Nigeria Meteorological Agency (NIMET). Temperature, wind speed and wind directions of sampling points were obtained using the appropriate instruments. Results showed that in Soku Community the first rain is the most polluted followed by the late rain while the mid rain is least, polluted due to discharge of gases and particulates from the atmosphere via washout, rainout, and dilution. It is therefore recommended that government regulatory agencies should put appropriate measures in place to monitor the quantity of gas emissions into the environment and also set and implement polluter pay principle for polluting industries and facilities.

Zenodo (CERN European Organization for Nuclear Research)
Federal University of Technology Owerri (NG)
Clean water and sanitation
Openalex Percentile: Top 68%
Oil, Gas, and Environmental Issues
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.