Analysis of Quality Parameters of Radiation Treatment Plans Using SRS (Stereotactic Radiosurgery) and SRT (Stereotactic Radiotherapy) – A Single Institution Six Year Experience

Aim: The study's aims were to assess key plan quality indicators, including the Conformity Index, Gradient Index, and Homogeneity Index, which had previously been evaluated using isodose lines and DVH. Materials and Methods: We reviewed the treatment plans for 37 retrospective cases that used the TrueBeam STx linac for stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) between 2019 and 2024. Treatment plans were evaluated using the following plan quality parameters suggested by Radiation Therapy Oncology Group [RTOG] such as Quality of Coverage [QRTOG], Homogeneity Index [HIRTOG] and Conformity Index [CIRTOG] Apart from that, Paddick’s Conformity Index [CIPaddick], Lomax Conformity Index [CILomax], New Conformity Index, Gradient Measure (GM), Gradient Index (GI), R50%, and Equivalent Fall-off Distance [EFOD]. Results: The percentage accuracies of CIRTOG, CIPaddick, CILomax that are as per the protocol are 83.7%, 67.6%, 87.5%, respectively. It was found that the plan quality metrics are independent of target volumes and shape. Conclusion: On analysis, all the plan quality parameters of patient treatment plans which were treated earlier was found to be within the protocol.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-05-20
DOI
https://doi.org/10.5281/zenodo.15471832
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Quality Parameters of Radiation Treatment Plans Using SRS (Stereotactic Radiosurgery) and SRT (Stereotactic Radiotherapy) – A Single Institution Six Year Experience

Zenodo (CERN European Organization for Nuclear Research)
Advanced Radiotherapy Techniques
article

Analysis of Quality Parameters of Radiation Treatment Plans Using SRS (Stereotactic Radiosurgery) and SRT (Stereotactic Radiotherapy) – A Single Institution Six Year Experience

article en

Abstract

Aim: The study's aims were to assess key plan quality indicators, including the Conformity Index, Gradient Index, and Homogeneity Index, which had previously been evaluated using isodose lines and DVH. Materials and Methods: We reviewed the treatment plans for 37 retrospective cases that used the TrueBeam STx linac for stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) between 2019 and 2024. Treatment plans were evaluated using the following plan quality parameters suggested by Radiation Therapy Oncology Group [RTOG] such as Quality of Coverage [QRTOG], Homogeneity Index [HIRTOG] and Conformity Index [CIRTOG] Apart from that, Paddick’s Conformity Index [CIPaddick], Lomax Conformity Index [CILomax], New Conformity Index, Gradient Measure (GM), Gradient Index (GI), R50%, and Equivalent Fall-off Distance [EFOD]. Results: The percentage accuracies of CIRTOG, CIPaddick, CILomax that are as per the protocol are 83.7%, 67.6%, 87.5%, respectively. It was found that the plan quality metrics are independent of target volumes and shape. Conclusion: On analysis, all the plan quality parameters of patient treatment plans which were treated earlier was found to be within the protocol.

Zenodo (CERN European Organization for Nuclear Research)
Good health and well-being
Openalex Percentile: Top 47%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.