CFD Analysis of SAH System Employing Different Rib Shapes

The purpose of this work is to conduct a computational analysis of a roughened solar air heater (SAH) using artificial roughness in the form of several types of ribs. A solar air heater is a kind of heat exchanger that uses sun radiation to produce heat energy. Smooth solar air heaters are considered inefficient because of the poor convective heat transfer coefficient from the absorber plate to the air. To improve the heat transfer rate, artificial roughness is used in the form of double concave ribs. The geometric variables that will be selected are relative roughness height (e/D), relative roughness pitch (P/e), and relative arc radius (r/e). These variables will be analyzed at five different values of Reynolds number (Re), and their impact on heat transfer, friction factor, and thermohydraulic performance parameter (THPP) will be examined using commercial computational fluid dynamics (CFD) software, Ansys Fluent. After examining past studies, it has been concluded that the Nusselt number grows as the Reynolds number increases, and the opposite is true for the friction factor. However, when it comes to the relative arc radius (r/e), both the Nusselt number and the friction factor decrease as r/e increases. When a/H is increased from 0.2 to 0.5, the Nusselt number rises from 65.64 to 242.72, and the friction factor rises from 0.0806 to 0.2155 for the range of Re. The Nusselt number rises from 68.88 to 274.29, and the friction factor rises from 0.0876 to 0.6290 over the range of Re considered when e/H increases from 0.4 to 0.8 with a constant value of a/H of 0.3 and β of 30%. When β is increased from 13% to 30% while keeping e/H at a constant value of 0.4 and a/H at a constant value of 0.3, the Nusselt number reduces from 207.92 to 70.26, and the friction factor decreases from 0.1707 to 0.0877 across the range of Re. For a/H, the maximum Nusselt number enhancement and friction factor increment are determined to be 5.86 and 22.15, respectively. These values correspond to a/H of 0.5, e/H of 0.4, and an open area ratio of 30% for the Reynolds number range examined across the smooth duct.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-02-13
DOI
https://doi.org/10.5281/zenodo.14866923
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CFD Analysis of SAH System Employing Different Rib Shapes

Zenodo (CERN European Organization for Nuclear Research)
Heat Transfer Mechanisms
article

CFD Analysis of SAH System Employing Different Rib Shapes

article en

Abstract

The purpose of this work is to conduct a computational analysis of a roughened solar air heater (SAH) using artificial roughness in the form of several types of ribs. A solar air heater is a kind of heat exchanger that uses sun radiation to produce heat energy. Smooth solar air heaters are considered inefficient because of the poor convective heat transfer coefficient from the absorber plate to the air. To improve the heat transfer rate, artificial roughness is used in the form of double concave ribs. The geometric variables that will be selected are relative roughness height (e/D), relative roughness pitch (P/e), and relative arc radius (r/e). These variables will be analyzed at five different values of Reynolds number (Re), and their impact on heat transfer, friction factor, and thermohydraulic performance parameter (THPP) will be examined using commercial computational fluid dynamics (CFD) software, Ansys Fluent. After examining past studies, it has been concluded that the Nusselt number grows as the Reynolds number increases, and the opposite is true for the friction factor. However, when it comes to the relative arc radius (r/e), both the Nusselt number and the friction factor decrease as r/e increases. When a/H is increased from 0.2 to 0.5, the Nusselt number rises from 65.64 to 242.72, and the friction factor rises from 0.0806 to 0.2155 for the range of Re. The Nusselt number rises from 68.88 to 274.29, and the friction factor rises from 0.0876 to 0.6290 over the range of Re considered when e/H increases from 0.4 to 0.8 with a constant value of a/H of 0.3 and β of 30%. When β is increased from 13% to 30% while keeping e/H at a constant value of 0.4 and a/H at a constant value of 0.3, the Nusselt number reduces from 207.92 to 70.26, and the friction factor decreases from 0.1707 to 0.0877 across the range of Re. For a/H, the maximum Nusselt number enhancement and friction factor increment are determined to be 5.86 and 22.15, respectively. These values correspond to a/H of 0.5, e/H of 0.4, and an open area ratio of 30% for the Reynolds number range examined across the smooth duct.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 57%
Heat Transfer Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.