Mycological analysis in three schools over four seasons using passive air sedimentation

The aim of the study is the isolation and identification of fungi using passive air sedimentation. This study analyzed 540 mycological samples from three primary schools in Zenica, collected in September, December, February, and May. Each season, 135 samples were taken from five rooms (two classrooms, a gym, a locker room, and a library) in each school. Samples were collected three times daily at three different heights with 15-minute exposure times. Samples were refrigerated and transported in sterile bags, incubated for 24 hours, and inoculated on specific agars with and without additives. Plates were incubated at 37°C and 25°C for up to 7 days, followed by examinations. Petri dishes were used for passive air sampling, and colonies were counted after incubation. The average number of microorganisms (CFU/m³) was calculated using Omeliansky’s method. Statistical methods included the Chi-squared test and p-value. Colony appearance was assessed visually and microscopically using a light microscope. Growth rate, size, structure, and color changes were monitored. In September, the highest mold concentrations were at H. Kikić Primary School (796 CFU/m³, not significant), M. Dizdar Primary School (1260 CFU/m³, not significant), and A. Šantić Primary School (3980 CFU/m³, significant). Penicillium spp. and Alternaria spp. were most prevalent, with Alternaria spp. significant at H. Kikić Primary School. In December, the highest mold/yeast concentrations were at H. Kikić Primary School (4578 CFU/m³, not significant), M. Dizdar Primary School (1924 CFU/m³, significant), and A. Šantić Primary School (2587 CFU/m³, not significant). Penicillium spp. was most prevalent. In February, the highest mold concentrations were at H. Kikić Primary School (4578 CFU/m³, not significant), M. Dizdar Primary School (2786 CFU/m³, not significant), and A. Šantić Primary School (5838 CFU/m³, significant). Aspergillus spp. and Penicillium spp. were equally prevalent. In May, the highest mold/yeast concentrations were at H. Kikić Primary School (6568 CFU/m³, significant), M. Dizdar Primary School (3516 CFU/m³, significant), and A. Šantić Primary School (7431 CFU/m³, significant). Aspergillus spp. was most prevalent. These findings highlight the importance of regular monitoring and implementing appropriate ventilation measures to manage air quality and health concerns in schools.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-10-30
DOI
https://doi.org/10.5281/zenodo.15019409
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mycological analysis in three schools over four seasons using passive air sedimentation

Zenodo (CERN European Organization for Nuclear Research)
Indoor Air Quality and Microbial Exposure
article

Mycological analysis in three schools over four seasons using passive air sedimentation

article en

Abstract

The aim of the study is the isolation and identification of fungi using passive air sedimentation. This study analyzed 540 mycological samples from three primary schools in Zenica, collected in September, December, February, and May. Each season, 135 samples were taken from five rooms (two classrooms, a gym, a locker room, and a library) in each school. Samples were collected three times daily at three different heights with 15-minute exposure times. Samples were refrigerated and transported in sterile bags, incubated for 24 hours, and inoculated on specific agars with and without additives. Plates were incubated at 37°C and 25°C for up to 7 days, followed by examinations. Petri dishes were used for passive air sampling, and colonies were counted after incubation. The average number of microorganisms (CFU/m³) was calculated using Omeliansky’s method. Statistical methods included the Chi-squared test and p-value. Colony appearance was assessed visually and microscopically using a light microscope. Growth rate, size, structure, and color changes were monitored. In September, the highest mold concentrations were at H. Kikić Primary School (796 CFU/m³, not significant), M. Dizdar Primary School (1260 CFU/m³, not significant), and A. Šantić Primary School (3980 CFU/m³, significant). Penicillium spp. and Alternaria spp. were most prevalent, with Alternaria spp. significant at H. Kikić Primary School. In December, the highest mold/yeast concentrations were at H. Kikić Primary School (4578 CFU/m³, not significant), M. Dizdar Primary School (1924 CFU/m³, significant), and A. Šantić Primary School (2587 CFU/m³, not significant). Penicillium spp. was most prevalent. In February, the highest mold concentrations were at H. Kikić Primary School (4578 CFU/m³, not significant), M. Dizdar Primary School (2786 CFU/m³, not significant), and A. Šantić Primary School (5838 CFU/m³, significant). Aspergillus spp. and Penicillium spp. were equally prevalent. In May, the highest mold/yeast concentrations were at H. Kikić Primary School (6568 CFU/m³, significant), M. Dizdar Primary School (3516 CFU/m³, significant), and A. Šantić Primary School (7431 CFU/m³, significant). Aspergillus spp. was most prevalent. These findings highlight the importance of regular monitoring and implementing appropriate ventilation measures to manage air quality and health concerns in schools.

Zenodo (CERN European Organization for Nuclear Research)
University of Tuzla (BA)
Openalex Percentile: Top 58%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.