Efficacious Detection of Epinephrine in the Midst of an Interference (ASCORBIC ACID) Employing Designed Gold Electrode with Cobalt Octacarboxyphenoxy Phthalocyanines

<p>The modification of gold electrode with cobalt octacarboxyphenoxy phthalocyanines (CoOcPhOPc), for the pH selective detection of epinephrine was investigated. 1,4-phenylene diamine dihydrochloride (PA) was electrografted onto gold electrode and CoOcPhOPc was immobilized on the electrode via amide bond coupling. The modified electrode (Au-PA-CoOcPhOPc) was characterized with voltammetry and impedance studies. The modified electrode demonstrated high sensitivity and good selectivity with low limit of detection (LOD) of 0.27 nM at 3σ, limit of quantitation (LOQ) of 0.9 nM at 10σ and high sensitivity of 0.6 ± 0.01 nA nM-1 towards the detection of epinephrine (EP). The reusability, stability and reproducibility of the electrode were confirmed for the detection with cyclic voltammetry (CV). The calibration curves showed very good and strong positive linear relationship with correlation coeffient of +0.99. The calibration curve of the square root of the scan rate confirmed the detection and the process of the reaction to be diffusion controlled.</p>

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-03-06
DOI
https://doi.org/10.5281/zenodo.14979817
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacious Detection of Epinephrine in the Midst of an Interference (ASCORBIC ACID) Employing Designed Gold Electrode with Cobalt Octacarboxyphenoxy Phthalocyanines

Zenodo (CERN European Organization for Nuclear Research)
Electrochemical sensors and biosensors
article

Efficacious Detection of Epinephrine in the Midst of an Interference (ASCORBIC ACID) Employing Designed Gold Electrode with Cobalt Octacarboxyphenoxy Phthalocyanines

article en

Abstract

<p>The modification of gold electrode with cobalt octacarboxyphenoxy phthalocyanines (CoOcPhOPc), for the pH selective detection of epinephrine was investigated. 1,4-phenylene diamine dihydrochloride (PA) was electrografted onto gold electrode and CoOcPhOPc was immobilized on the electrode via amide bond coupling. The modified electrode (Au-PA-CoOcPhOPc) was characterized with voltammetry and impedance studies. The modified electrode demonstrated high sensitivity and good selectivity with low limit of detection (LOD) of 0.27 nM at 3σ, limit of quantitation (LOQ) of 0.9 nM at 10σ and high sensitivity of 0.6 ± 0.01 nA nM-1 towards the detection of epinephrine (EP). The reusability, stability and reproducibility of the electrode were confirmed for the detection with cyclic voltammetry (CV). The calibration curves showed very good and strong positive linear relationship with correlation coeffient of +0.99. The calibration curve of the square root of the scan rate confirmed the detection and the process of the reaction to be diffusion controlled.</p>

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 57%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.