ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF MUPIRICON OINMENTS BY RP-HPLC METHODS

A simple, economical, specific, accurate, precise and validated reverse-phase high-performance liquid chromatography (RP-HPLC) method has been developed for the assay study of Mupirocin Ointment in the pharmaceutical dosage form. The chromatographic separation was achieved on C-18 column (300 mm x 3.9 mm, 10 µ particle size) at 25℃ temperature using mobile phase Phosphate Buffer : Acetonitrile(ACN) (75:25 % v/v) at flow rate 1.0 ml/min. Quantification was achieved with a UV detector at 229 nm. The retention time of Mupirocin USP was found to be 6.696 ± 0.05 min. The proposed method was validated according to ICH guidelines concerning assay studies for Mupirocin ointment. The developed method with good separation successfully applied for the determination of Mupirocin in its pharmaceutical dosage form. Keywords : RP-HPLC, Mupirocin, Assay, Chromatography, ICH Guidelines.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-06-17
DOI
https://doi.org/10.5281/zenodo.15684340
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF MUPIRICON OINMENTS BY RP-HPLC METHODS

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF MUPIRICON OINMENTS BY RP-HPLC METHODS

article en

Abstract

A simple, economical, specific, accurate, precise and validated reverse-phase high-performance liquid chromatography (RP-HPLC) method has been developed for the assay study of Mupirocin Ointment in the pharmaceutical dosage form. The chromatographic separation was achieved on C-18 column (300 mm x 3.9 mm, 10 µ particle size) at 25℃ temperature using mobile phase Phosphate Buffer : Acetonitrile(ACN) (75:25 % v/v) at flow rate 1.0 ml/min. Quantification was achieved with a UV detector at 229 nm. The retention time of Mupirocin USP was found to be 6.696 ± 0.05 min. The proposed method was validated according to ICH guidelines concerning assay studies for Mupirocin ointment. The developed method with good separation successfully applied for the determination of Mupirocin in its pharmaceutical dosage form. Keywords : RP-HPLC, Mupirocin, Assay, Chromatography, ICH Guidelines.

Zenodo (CERN European Organization for Nuclear Research)
Industry, innovation and infrastructure
Openalex Percentile: Top 56%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.