Evaluation of a Bilateral Tele-Echographic Architecture in Presence of Time Delay

Tele-ecography with force-feedback aims at remotely reproducing ultrasound examination. Current state-of-the-art tele-echography systems have been tested on phantoms or humans, but in non-realistic conditions. In fact, most of them do not consider the presence of time delay (that is a source of instability in all teleoperation tasks) or they do not establish sufficient contact forces according to ultrasound requirements. Moreover, none of these architectures take advantage of a robotic solution to relieve doctor's fatigue, which has been demonstrated source of work-related musculoskeletal disorders (WRMSD). This paper aims to evaluate the performance of a proposed tele-echography architecture under realistic working conditions, which are the presence of time delay and ultrasound-required contact forces. To deal with instability, two separate transmission networks were implemented and the teleoperation one was passivated according to Time Domain Passivity Approach. Moreover, a user-dependent scaling factor on the force-feedback is proposed to deal with WRMSD. The system has been tested by a single user contacting a custom-made gelatin phantom to identify an immersed screw. The architecture was found successful in the task exhibiting a stable behaviour in presence of 400 ms round trip delay and with contact of 20 N.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-10-25
DOI
https://doi.org/10.5281/zenodo.14731108
Primary Topic
Teleoperation and Haptic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a Bilateral Tele-Echographic Architecture in Presence of Time Delay

Zenodo (CERN European Organization for Nuclear Research)
Teleoperation and Haptic Systems
article

Evaluation of a Bilateral Tele-Echographic Architecture in Presence of Time Delay

article en

Abstract

Tele-ecography with force-feedback aims at remotely reproducing ultrasound examination. Current state-of-the-art tele-echography systems have been tested on phantoms or humans, but in non-realistic conditions. In fact, most of them do not consider the presence of time delay (that is a source of instability in all teleoperation tasks) or they do not establish sufficient contact forces according to ultrasound requirements. Moreover, none of these architectures take advantage of a robotic solution to relieve doctor's fatigue, which has been demonstrated source of work-related musculoskeletal disorders (WRMSD). This paper aims to evaluate the performance of a proposed tele-echography architecture under realistic working conditions, which are the presence of time delay and ultrasound-required contact forces. To deal with instability, two separate transmission networks were implemented and the teleoperation one was passivated according to Time Domain Passivity Approach. Moreover, a user-dependent scaling factor on the force-feedback is proposed to deal with WRMSD. The system has been tested by a single user contacting a custom-made gelatin phantom to identify an immersed screw. The architecture was found successful in the task exhibiting a stable behaviour in presence of 400 ms round trip delay and with contact of 20 N.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 68%
Teleoperation and Haptic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.