DETERMINATION OF COBALT IN DIFFERENT OXIDATION STATES IN COBALT(II)-BASED COMPLEXONATE MICRONUTRIENT FERTILIZERS BY SPECTROSCOPIC METHODS

The study explores the impact of acid nature, pH, and an excess of Trilon B on the selectivity of determination and the ability to separately quantify Cobalt(II) and Cobalt(III) forms in micronutrient fertilizers based on cobalt(II) complexonates. Photometric methods were developed to determine the content of Cobalt(II) and Cobalt(III), as well as an atomic absorption method for determining total cobalt, for the quality control of the micronutrient fertilizer. The correctness of the developed methods was confirmed, and their metrological characteristics were calculated. The determination time is 20 minutes. The relative standard deviation does not exceed 0.02 for the photometric method and 0.03 for the atomic absorption method.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-02-28
DOI
https://doi.org/10.5281/zenodo.14923119
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DETERMINATION OF COBALT IN DIFFERENT OXIDATION STATES IN COBALT(II)-BASED COMPLEXONATE MICRONUTRIENT FERTILIZERS BY SPECTROSCOPIC METHODS

Zenodo (CERN European Organization for Nuclear Research)
Water Quality Monitoring and Analysis
article

DETERMINATION OF COBALT IN DIFFERENT OXIDATION STATES IN COBALT(II)-BASED COMPLEXONATE MICRONUTRIENT FERTILIZERS BY SPECTROSCOPIC METHODS

article en

Abstract

The study explores the impact of acid nature, pH, and an excess of Trilon B on the selectivity of determination and the ability to separately quantify Cobalt(II) and Cobalt(III) forms in micronutrient fertilizers based on cobalt(II) complexonates. Photometric methods were developed to determine the content of Cobalt(II) and Cobalt(III), as well as an atomic absorption method for determining total cobalt, for the quality control of the micronutrient fertilizer. The correctness of the developed methods was confirmed, and their metrological characteristics were calculated. The determination time is 20 minutes. The relative standard deviation does not exceed 0.02 for the photometric method and 0.03 for the atomic absorption method.

Zenodo (CERN European Organization for Nuclear Research)
Donetsk State University of Management (UA)
Zero hunger
Openalex Percentile: Top 51%
Water Quality Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.