Verification of analytical performance of the C- peptide assay on the Abbott Alinity ci®: Experience of the central laboratory of Mohammed VI University Hospital of Oujda

The objective of our study was to assess the analytical performance of C- peptide determination using a two-step immunoassay with microparticle chemiluminescence immunoassay (CMIA) technology, adhering to Scope A criteria outlined in the guide for the verification/validation of medical biology methods. We analyzed the C- peptide assay's intermediate precision and reproducibility. For the three levels (low, medium, and high), the obtained results are very satisfactory. For intermediate fidelity, the coefficients of variation are 2.52%, CV2 = 3.70%, and CV3 = 4.37%, respectively. For repeatability, the results): CV1 = 3.15%, CV2 = 1.65%, and CV3 = 1.55%, respectively. The obtained results enabled verification of method performance and comparison with predefined analytical objectives to ensure compliance with regulatory and normative standards. The central laboratory at University Hospital Mohammed VI of Oujda adheres to a quality policy focused on mastering various analytical systems.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-08-30
DOI
https://doi.org/10.5281/zenodo.14676510
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Verification of analytical performance of the C- peptide assay on the Abbott Alinity ci®: Experience of the central laboratory of Mohammed VI University Hospital of Oujda

Zenodo (CERN European Organization for Nuclear Research)
Biosensors and Analytical Detection
article

Verification of analytical performance of the C- peptide assay on the Abbott Alinity ci®: Experience of the central laboratory of Mohammed VI University Hospital of Oujda

article en

Abstract

The objective of our study was to assess the analytical performance of C- peptide determination using a two-step immunoassay with microparticle chemiluminescence immunoassay (CMIA) technology, adhering to Scope A criteria outlined in the guide for the verification/validation of medical biology methods. We analyzed the C- peptide assay's intermediate precision and reproducibility. For the three levels (low, medium, and high), the obtained results are very satisfactory. For intermediate fidelity, the coefficients of variation are 2.52%, CV2 = 3.70%, and CV3 = 4.37%, respectively. For repeatability, the results): CV1 = 3.15%, CV2 = 1.65%, and CV3 = 1.55%, respectively. The obtained results enabled verification of method performance and comparison with predefined analytical objectives to ensure compliance with regulatory and normative standards. The central laboratory at University Hospital Mohammed VI of Oujda adheres to a quality policy focused on mastering various analytical systems.

Zenodo (CERN European Organization for Nuclear Research)
Mohamed I University (MA)
Partnerships for the goals
Openalex Percentile: Top 72%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Verification of analytical performance of the C- peptide assay on the Abbott Alinity ci®: Experience of the central laboratory of Mohammed VI University Hospital of Oujda · Zenodo (CERN European Organization for Nuclear Research) (2024) | TGRS Research Map | TGRS