APPROBATION OF METHODS FOR FLUORIMETRIC DETERMINATION OF PHOTOSYNTHETIC ACTIVITY OF PHYTOPLANKTON CELLS

Various FRR protocols were tested for registration of fluorescence induction curves of phytoplankton chlorophyll on a laboratory test culture Chlorella sorokiniana, as well as on cells of natural phytoplankton from the Kalmius and Krynka rivers. The results of successful field tests on the registration of fluorescence induction curves at the intensity of saturating pulses of 20, 30 and 50 thousand μmol.·quanta·m-2·s-1 with a duration of 1 μs with different time intervals: 1, 4, 9, 19, 29 and 49 μs with a total measurement duration of 1 second. It is shown that FRR protocols with pulse intervals of 1, 4 and 9 μs are the most suitable for measuring fluorescence in natural conditions.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-12-03
DOI
https://doi.org/10.5281/zenodo.14266057
Primary Topic
Marine and coastal ecosystems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

APPROBATION OF METHODS FOR FLUORIMETRIC DETERMINATION OF PHOTOSYNTHETIC ACTIVITY OF PHYTOPLANKTON CELLS

Zenodo (CERN European Organization for Nuclear Research)
Marine and coastal ecosystems
article

APPROBATION OF METHODS FOR FLUORIMETRIC DETERMINATION OF PHOTOSYNTHETIC ACTIVITY OF PHYTOPLANKTON CELLS

article en

Abstract

Various FRR protocols were tested for registration of fluorescence induction curves of phytoplankton chlorophyll on a laboratory test culture Chlorella sorokiniana, as well as on cells of natural phytoplankton from the Kalmius and Krynka rivers. The results of successful field tests on the registration of fluorescence induction curves at the intensity of saturating pulses of 20, 30 and 50 thousand μmol.·quanta·m-2·s-1 with a duration of 1 μs with different time intervals: 1, 4, 9, 19, 29 and 49 μs with a total measurement duration of 1 second. It is shown that FRR protocols with pulse intervals of 1, 4 and 9 μs are the most suitable for measuring fluorescence in natural conditions.

Zenodo (CERN European Organization for Nuclear Research)
Donetsk State University of Management (UA)
Openalex Percentile: Top 68%
Marine and coastal ecosystems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.