UV-SPECTOPHOTOMETRIC METHOD DEVELOPMENT AND VALIDATION OF SYNTHESIZED 7-HYDROXY-4-METHYL COUMARIN.

Objectives: The objectives of present workwastoo develop and standardize UV-Spectrophotometric method for estimation of 7-Hydroxy-4-Methyl Coumarin in marketed formulation. Materials and method: UV- Spectrophotometric method was developed using 70ml water: 30ml methanol as solvent. The developed method was standardized in terms of validation parameters such as simple, sensitive, precise, linear, accurate, robust, reproducible as per ICH Q2(R1) guidelines. For estimation of 7-Hydroxy-4-Methyl Coumarin in marketed formulation this newly developed method was successfully applied. Results: 7-Hydroxy-4-Methyl Coumarin exhibits λmax at 321nm in the Beer’s range 2 to 10μg/ml Beer’s law was obeyed. The limit of detection was found to be 0.84μg/ml and limit of quantification was found to be 2.54μg/ml. Recovery of 7-Hydroxy-4-Methyl Coumarin in marketed formulation was obtained in the range of 75-100%. All the precision range less than 2%. Conclusion:The method was found to be simple, accurate, environment friendly, reproducible and marketed API of 7-Hydroxy-4-Methyl Coumarin can be estimated.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-10-05
DOI
https://doi.org/10.5281/zenodo.13995175
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

UV-SPECTOPHOTOMETRIC METHOD DEVELOPMENT AND VALIDATION OF SYNTHESIZED 7-HYDROXY-4-METHYL COUMARIN.

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

UV-SPECTOPHOTOMETRIC METHOD DEVELOPMENT AND VALIDATION OF SYNTHESIZED 7-HYDROXY-4-METHYL COUMARIN.

article en

Abstract

Objectives: The objectives of present workwastoo develop and standardize UV-Spectrophotometric method for estimation of 7-Hydroxy-4-Methyl Coumarin in marketed formulation. Materials and method: UV- Spectrophotometric method was developed using 70ml water: 30ml methanol as solvent. The developed method was standardized in terms of validation parameters such as simple, sensitive, precise, linear, accurate, robust, reproducible as per ICH Q2(R1) guidelines. For estimation of 7-Hydroxy-4-Methyl Coumarin in marketed formulation this newly developed method was successfully applied. Results: 7-Hydroxy-4-Methyl Coumarin exhibits λmax at 321nm in the Beer’s range 2 to 10μg/ml Beer’s law was obeyed. The limit of detection was found to be 0.84μg/ml and limit of quantification was found to be 2.54μg/ml. Recovery of 7-Hydroxy-4-Methyl Coumarin in marketed formulation was obtained in the range of 75-100%. All the precision range less than 2%. Conclusion:The method was found to be simple, accurate, environment friendly, reproducible and marketed API of 7-Hydroxy-4-Methyl Coumarin can be estimated.

Zenodo (CERN European Organization for Nuclear Research)
Rajiv Gandhi University of Health Sciences (IN)
Life in Land
Openalex Percentile: Top 70%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.