Development And Validation of UV Spectroscopic Method for Estimation of Calcium Pantothenate in Bulk and Pharmaceutical Dosage Form

The study aims to develop and validate a UV-visible spectrophotometric method for analyzing Calcium Pantothenate. The method uses a solvent system of methanol and water (1:1), chosen for its solubility and cost-effectiveness. A stock solution (1000 µg/ml) and subsequent dilutions were prepared for analysis. The absorption maxima (λmax) of Calcium Pantothenate was determined to be 212 nm. Validation parameters included linearity , precision , accuracy , specificity , robustness , and sensitivity. Linearity was confirmed over the concentration range of 5 to 25 µg/ml, with an R² value of 0.999. Precision studies both intra-day and inter-day demonstrated consistency with %RSD values below 2%. Accuracy was verified using the standard addition method with recoveries within 100±2%. The method’s specificity was confirmed by comparing the UV spectra of the tablet and standard solutions with no interference from excipients. The developed method is thus validated as reliable and accurate for the quantitative analysis of Calcium Pantothenate.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-11-02
DOI
https://doi.org/10.5281/zenodo.14028818
Primary Topic
Neurological diseases and metabolism
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development And Validation of UV Spectroscopic Method for Estimation of Calcium Pantothenate in Bulk and Pharmaceutical Dosage Form

Zenodo (CERN European Organization for Nuclear Research)
Neurological diseases and metabolism
article

Development And Validation of UV Spectroscopic Method for Estimation of Calcium Pantothenate in Bulk and Pharmaceutical Dosage Form

article en

Abstract

The study aims to develop and validate a UV-visible spectrophotometric method for analyzing Calcium Pantothenate. The method uses a solvent system of methanol and water (1:1), chosen for its solubility and cost-effectiveness. A stock solution (1000 µg/ml) and subsequent dilutions were prepared for analysis. The absorption maxima (λmax) of Calcium Pantothenate was determined to be 212 nm. Validation parameters included linearity , precision , accuracy , specificity , robustness , and sensitivity. Linearity was confirmed over the concentration range of 5 to 25 µg/ml, with an R² value of 0.999. Precision studies both intra-day and inter-day demonstrated consistency with %RSD values below 2%. Accuracy was verified using the standard addition method with recoveries within 100±2%. The method’s specificity was confirmed by comparing the UV spectra of the tablet and standard solutions with no interference from excipients. The developed method is thus validated as reliable and accurate for the quantitative analysis of Calcium Pantothenate.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 64%
Neurological diseases and metabolism
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development And Validation of UV Spectroscopic Method for Estimation of Calcium Pantothenate in Bulk and Pharmaceutical Dosage Form · Zenodo (CERN European Organization for Nuclear Research) (2024) | TGRS Research Map | TGRS