Verification of analytical performance of Carcinoembryonic antigen assay on the Abbott Alinity ci®: Experience of the central laboratory of Mohammed VI University Hospital of Oujda

The aim of our study was the verification of the analytical performance of Carcinoembryonic antigen determination on the Abbott CI analyzer utilizing the immuno-chemiluminescence method. The verification process was conducted in the biochemistry laboratory of Mohammed VI University Hospital of Oujda. The working methodology adapted is based on the recommendations of the protocol of the French accreditation committee (COFRAC) accreditation technical guide (GTA) 04, by the evaluation of reproducibility and repeatability. The results obtained by this evaluation were overall satisfactory and have meet the recommended criteria set by supplier and the French society of clinical biology. This study shows that the biochemistry laboratory of Mohammed VI University Hospital of Oujda can deliver an accurate and precise results which can be used for clinical diagnosis and decision making.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-08-30
DOI
https://doi.org/10.5281/zenodo.15004152
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Verification of analytical performance of Carcinoembryonic antigen assay on the Abbott Alinity ci®: Experience of the central laboratory of Mohammed VI University Hospital of Oujda

Zenodo (CERN European Organization for Nuclear Research)
Radiopharmaceutical Chemistry and Applications
article

Verification of analytical performance of Carcinoembryonic antigen assay on the Abbott Alinity ci®: Experience of the central laboratory of Mohammed VI University Hospital of Oujda

article en

Abstract

The aim of our study was the verification of the analytical performance of Carcinoembryonic antigen determination on the Abbott CI analyzer utilizing the immuno-chemiluminescence method. The verification process was conducted in the biochemistry laboratory of Mohammed VI University Hospital of Oujda. The working methodology adapted is based on the recommendations of the protocol of the French accreditation committee (COFRAC) accreditation technical guide (GTA) 04, by the evaluation of reproducibility and repeatability. The results obtained by this evaluation were overall satisfactory and have meet the recommended criteria set by supplier and the French society of clinical biology. This study shows that the biochemistry laboratory of Mohammed VI University Hospital of Oujda can deliver an accurate and precise results which can be used for clinical diagnosis and decision making.

Zenodo (CERN European Organization for Nuclear Research)
Mohamed I University (MA)
Peace, Justice and strong institutions, Gender equality
Openalex Percentile: Top 53%
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.