Influence of pre-existing defects on corrosion performance of Cr coatings

THis is a poster presented at the 2024 Annual MIDAS meeting held at the Henry Royce Institute, University of Manchester, on the 16th of September 2024. The poster covers a study looking a tthe impact of pre-existing cracks on the corrosion performance of chromium coated zirconium alloy cladding tubes. Cracks were introduced to the coating by mehcanical deforming cladding tubes under uniaxial tension in the axial direction up to a strain of 2%. Four different coatings candidtates were exmained including a Nitrogen Cold Spray (NCS) and three differnt Magnetron Sputtered Physical Vapour Deposited (MS-PVD) coatings, labeled PVD a, b and c. PVDa and b had been produced using the same susbtrate bias but with different coating thicknesses, whilst PVD c was produced at a different substrate bias. The samples were autoclaved in pressurised water reactor (PWR) chemistry at 360 degrees celcius for 25 days with a subsequent autoclave test performed at the same temperature and with the same chemistry but using deuterium spiked water for 28 days. The samples were then cross sectioned to reveal the circumferential cracks and were imaged using electorn microscopy to analyse crack density, crack opening and oxide area. The cross sectioned samples were anaylsed using NanoSIMS to invesitgate the relative location of Deuterium within the microstrucutre as a result of the second autoclave tests. The coatings demonstrated enhanced oxidation resistance compared to the uncoated cladding. While larger oxides can lead to blistering and increase the risk of delamination, they are typically associated with large crack openings in PVD coatings. A reduced crack density can lead to fewer cracks with a greater cack opening that allow for larger oxide formation, whereas higher crack densities contribute to a greater overall area of oxide islands at the Cr-Zr interface. The complex crack networks observed in NCS coatings, however, appear to reduce oxide size and limit deuterium presence at the interface.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-09-16
DOI
https://doi.org/10.5281/zenodo.13884591
Primary Topic
Nuclear Materials and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of pre-existing defects on corrosion performance of Cr coatings

Zenodo (CERN European Organization for Nuclear Research)
Nuclear Materials and Properties
article

Influence of pre-existing defects on corrosion performance of Cr coatings

article en

Abstract

THis is a poster presented at the 2024 Annual MIDAS meeting held at the Henry Royce Institute, University of Manchester, on the 16th of September 2024. The poster covers a study looking a tthe impact of pre-existing cracks on the corrosion performance of chromium coated zirconium alloy cladding tubes. Cracks were introduced to the coating by mehcanical deforming cladding tubes under uniaxial tension in the axial direction up to a strain of 2%. Four different coatings candidtates were exmained including a Nitrogen Cold Spray (NCS) and three differnt Magnetron Sputtered Physical Vapour Deposited (MS-PVD) coatings, labeled PVD a, b and c. PVDa and b had been produced using the same susbtrate bias but with different coating thicknesses, whilst PVD c was produced at a different substrate bias. The samples were autoclaved in pressurised water reactor (PWR) chemistry at 360 degrees celcius for 25 days with a subsequent autoclave test performed at the same temperature and with the same chemistry but using deuterium spiked water for 28 days. The samples were then cross sectioned to reveal the circumferential cracks and were imaged using electorn microscopy to analyse crack density, crack opening and oxide area. The cross sectioned samples were anaylsed using NanoSIMS to invesitgate the relative location of Deuterium within the microstrucutre as a result of the second autoclave tests. The coatings demonstrated enhanced oxidation resistance compared to the uncoated cladding. While larger oxides can lead to blistering and increase the risk of delamination, they are typically associated with large crack openings in PVD coatings. A reduced crack density can lead to fewer cracks with a greater cack opening that allow for larger oxide formation, whereas higher crack densities contribute to a greater overall area of oxide islands at the Cr-Zr interface. The complex crack networks observed in NCS coatings, however, appear to reduce oxide size and limit deuterium presence at the interface.

Zenodo (CERN European Organization for Nuclear Research)
Manchester Metropolitan University (GB), National Nuclear Laboratory (GB), University of Derby (GB), University of Manchester (GB), Henry Royce Institute (GB), Westinghouse Electric (Sweden) (SE), Jacobs (United Kingdom) (GB)
Openalex Percentile: Top 79%
Nuclear Materials and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.