Mitral Valve Repair with the Semi-Rigid Memo 4D Annuloplasty Ring : Early Clinical and Echocardiographic Outcomes from the MANTRA Study

OBJECTIVES Memo 4D is a semi-rigid ring with an exclusive saddle shape and progressive increased anteroposterior diameter. This preliminary analysis reports 30-day clinical and haemodynamic outcomes of the MANTRA Memo 4D sub-study. METHODS MANTRA is an 'umbrella' prospective, multicentre, worldwide post-market study to collect real-life safety and performance data on the Corcym devices. Clinical and echocardiographic outcomes were gathered preoperatively, at discharge and each follow-up. KCCQ-12 questionnaires were collected preoperatively and at 30 days. Echocardiographic studies were performed per a predefined protocol and assessed by an independent core laboratory. RESULTS In total, 166 patients (52, 31.3% female, mean age 60.7 ± 11.4 years) underwent mitral valve repair with Memo 4D in 17 international institutions between July 2021 and June 2023 (enrolment is still ongoing). Primary was the most common aetiology (157, 94.6%), of which 33 cases of Barlow's disease (19.9%); secondary mitral regurgitation was present in six cases (3.6%). Thirty-day mortality was 0.6% (1). One stroke event (0.6%), one acute kidney failure (0.6%), one myocardial infarction (0.6%) and two reoperations within 30 days were reported. Surgery marked improvement in the patient's NYHA class associated with a significant increase in KCCQ-12 summary score, from 69.1 (SD = 23.7) preoperatively to 83.9 (SD = 15.7) at 30 days. End-diastolic left ventricular diameters decreased from 55.19 (SD = 7.10) preoperatively to 52.70 (SD = 3.76) mm at 30 days, and left atrial volume decreased from 125.79 (SD = 46.33) preoperatively to 91.51 (SD = 37.20) ml at 30 days. Mitral regurgitation significantly reduced after the operation and up to 30-day follow-up. CONCLUSIONS Mitral valve repair with Memo 4D is associated with good clinical and haemodynamic outcomes in the early period.MANTRA ClinicalTrials.gov number NCT05002543.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2024-12-25
DOI
https://doi.org/10.5167/uzh-267398
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitral Valve Repair with the Semi-Rigid Memo 4D Annuloplasty Ring : Early Clinical and Echocardiographic Outcomes from the MANTRA Study

Zurich Open Repository and Archive (University of Zurich)
Cardiac Valve Diseases and Treatments
article

Mitral Valve Repair with the Semi-Rigid Memo 4D Annuloplasty Ring : Early Clinical and Echocardiographic Outcomes from the MANTRA Study

article en

Abstract

OBJECTIVES Memo 4D is a semi-rigid ring with an exclusive saddle shape and progressive increased anteroposterior diameter. This preliminary analysis reports 30-day clinical and haemodynamic outcomes of the MANTRA Memo 4D sub-study. METHODS MANTRA is an 'umbrella' prospective, multicentre, worldwide post-market study to collect real-life safety and performance data on the Corcym devices. Clinical and echocardiographic outcomes were gathered preoperatively, at discharge and each follow-up. KCCQ-12 questionnaires were collected preoperatively and at 30 days. Echocardiographic studies were performed per a predefined protocol and assessed by an independent core laboratory. RESULTS In total, 166 patients (52, 31.3% female, mean age 60.7 ± 11.4 years) underwent mitral valve repair with Memo 4D in 17 international institutions between July 2021 and June 2023 (enrolment is still ongoing). Primary was the most common aetiology (157, 94.6%), of which 33 cases of Barlow's disease (19.9%); secondary mitral regurgitation was present in six cases (3.6%). Thirty-day mortality was 0.6% (1). One stroke event (0.6%), one acute kidney failure (0.6%), one myocardial infarction (0.6%) and two reoperations within 30 days were reported. Surgery marked improvement in the patient's NYHA class associated with a significant increase in KCCQ-12 summary score, from 69.1 (SD = 23.7) preoperatively to 83.9 (SD = 15.7) at 30 days. End-diastolic left ventricular diameters decreased from 55.19 (SD = 7.10) preoperatively to 52.70 (SD = 3.76) mm at 30 days, and left atrial volume decreased from 125.79 (SD = 46.33) preoperatively to 91.51 (SD = 37.20) ml at 30 days. Mitral regurgitation significantly reduced after the operation and up to 30-day follow-up. CONCLUSIONS Mitral valve repair with Memo 4D is associated with good clinical and haemodynamic outcomes in the early period.MANTRA ClinicalTrials.gov number NCT05002543.

Zurich Open Repository and Archive (University of Zurich)
Openalex Percentile: Top 52%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mitral Valve Repair with the Semi-Rigid Memo 4D Annuloplasty Ring : Early Clinical and Echocardiographic Outcomes from the MANTRA Study · Zurich Open Repository and Archive (University of Zurich) (2024) | TGRS Research Map | TGRS