The Contralateral Ankle Joint Is a Reliable Reference for Testing Syndesmotic Stability Using Bilateral External Torque CT

BACKGROUND: Subtle chronic or latent instabilities are difficult to delineate with currently available diagnostic modalities and do not allow assessment of ligamentous functionality. The noninvasive bilateral external torque computed tomography (CT) was able to reliably detect syndesmotic lesions in a cadaveric study. The aim of the study was to test the external torque device in young, healthy subjects at 3 different torque levels and to demonstrate comparability with the contralateral side. METHODS: Ten healthy subjects without history of injury or surgery to the ankle joint were enrolled in this cross-sectional study. Four CT scans were performed. During the scans, the lower legs and feet were placed in an external torque device with predefined external rotation torques of 0, 2.5, 5, and 7.5 Nm. Five different radiographic measures of syndesmotic stability were measured: anterior distance (AD), tibiofibular clear space (TCS), posterior distance (PD), external rotation (ER), and beta angle. RESULTS: With increasing external torque, slight increases in AD, ER, and beta angle were observed, whereas TCS and PD decreased slightly. Large absolute differences were found between the healthy subjects for all measured parameters, regardless of the external torque applied. Differences from the contralateral side using the same external torque were minimal for all parameters, but smallest for AD with a maximum difference of 0.5 mm. CONCLUSION: Using the healthy contralateral ankle joint is appropriate for assessing syndesmotic stability based on minimal intraindividual side differences using the external torque device. Side differences >0.5 mm in AD and >0.9 mm in PD may be considered abnormal and may indicate significant instability of the syndesmosis. However, future studies are needed to define definitive cutoff values for relevant side differences in acute and chronic syndesmotic instability to guide clinicians in their treatment decisions.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2024-09-01
DOI
https://doi.org/10.5167/uzh-269316
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Contralateral Ankle Joint Is a Reliable Reference for Testing Syndesmotic Stability Using Bilateral External Torque CT

Zurich Open Repository and Archive (University of Zurich)
Foot and Ankle Surgery
article

The Contralateral Ankle Joint Is a Reliable Reference for Testing Syndesmotic Stability Using Bilateral External Torque CT

article en

Abstract

BACKGROUND: Subtle chronic or latent instabilities are difficult to delineate with currently available diagnostic modalities and do not allow assessment of ligamentous functionality. The noninvasive bilateral external torque computed tomography (CT) was able to reliably detect syndesmotic lesions in a cadaveric study. The aim of the study was to test the external torque device in young, healthy subjects at 3 different torque levels and to demonstrate comparability with the contralateral side. METHODS: Ten healthy subjects without history of injury or surgery to the ankle joint were enrolled in this cross-sectional study. Four CT scans were performed. During the scans, the lower legs and feet were placed in an external torque device with predefined external rotation torques of 0, 2.5, 5, and 7.5 Nm. Five different radiographic measures of syndesmotic stability were measured: anterior distance (AD), tibiofibular clear space (TCS), posterior distance (PD), external rotation (ER), and beta angle. RESULTS: With increasing external torque, slight increases in AD, ER, and beta angle were observed, whereas TCS and PD decreased slightly. Large absolute differences were found between the healthy subjects for all measured parameters, regardless of the external torque applied. Differences from the contralateral side using the same external torque were minimal for all parameters, but smallest for AD with a maximum difference of 0.5 mm. CONCLUSION: Using the healthy contralateral ankle joint is appropriate for assessing syndesmotic stability based on minimal intraindividual side differences using the external torque device. Side differences >0.5 mm in AD and >0.9 mm in PD may be considered abnormal and may indicate significant instability of the syndesmosis. However, future studies are needed to define definitive cutoff values for relevant side differences in acute and chronic syndesmotic instability to guide clinicians in their treatment decisions.

Zurich Open Repository and Archive (University of Zurich)
Good health and well-being
Openalex Percentile: Top 61%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.