Delayed Ferumoxtran‐10‐Enhanced Magnetic Resonance Neurography of the Lumbosacral Plexus: Impact on Vascular Suppression and Image Quality

Background Intravenous Ferumoxtran‐10 belongs to ultra‐small superparamagnetic iron oxide particles and can be used for magnetic resonance neurography (MRN) as an alternative to other imaging methods which use contrast agents. Purpose To examine the impact of intravenous Ferumoxtran‐10 on vascular suppression and compare image quality to gadolinium (Gd)‐enhanced image acquisition in MRN of lumbosacral plexus (LS). Study Type Prospective. Population/Subjects 17 patients with Ferumoxtran‐10‐enhanced MRN, and 20 patients with Gd‐enhanced MRN. Fieldstrength/Sequence 3T/3D STIR sequence. Assessment Image quality, nerve visibility and vascular suppression were evaluated by 3 readers using a 5‐point Likert scale. Statistical Tests Inter‐reader agreement (IRA) was calculated using intraclass coefficients (ICC). Quantitative analysis of image quality was performed by signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) measurements and compared using Student's t‐testing. Results Image quality, nerve visibility and vascular suppression were significantly higher for Ferumoxtran‐10‐enhanced MRN compared to Gd‐enhanced MRN sequences (p < 0.05). IRA for image quality of nerves was good in Gd‐enhanced and Ferumoxtran‐10 MRN with ICC values of 0.76 and 0.89, respectively. IRA for nerve visibility was good in Gd‐ and Ferumoxtran‐10 enhanced MR neurography (ICC 0.72 and 0.90). Mean SNR was significantly higher in Ferumoxtran‐10‐enhanced MRN for all analyzed structures, while mean CNR was for significantly better for S1 ganglion and femoral nerve in Ferumoxtran‐10‐enhanced MRN (p < 0.05). Data Conclusion Ferumoxtran‐10‐enhanced MRN of the LS plexus showed significantly higher image quality and nerve visibility with better vascular suppression as compared to Gd‐enhanced MRN. Evidence Level 2Technical EfficacyStage 3

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2025-04-01
DOI
https://doi.org/10.5167/uzh-264744
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Delayed Ferumoxtran‐10‐Enhanced Magnetic Resonance Neurography of the Lumbosacral Plexus: Impact on Vascular Suppression and Image Quality

Zurich Open Repository and Archive (University of Zurich)
Advanced MRI Techniques and Applications
article

Delayed Ferumoxtran‐10‐Enhanced Magnetic Resonance Neurography of the Lumbosacral Plexus: Impact on Vascular Suppression and Image Quality

article en

Abstract

Background Intravenous Ferumoxtran‐10 belongs to ultra‐small superparamagnetic iron oxide particles and can be used for magnetic resonance neurography (MRN) as an alternative to other imaging methods which use contrast agents. Purpose To examine the impact of intravenous Ferumoxtran‐10 on vascular suppression and compare image quality to gadolinium (Gd)‐enhanced image acquisition in MRN of lumbosacral plexus (LS). Study Type Prospective. Population/Subjects 17 patients with Ferumoxtran‐10‐enhanced MRN, and 20 patients with Gd‐enhanced MRN. Fieldstrength/Sequence 3T/3D STIR sequence. Assessment Image quality, nerve visibility and vascular suppression were evaluated by 3 readers using a 5‐point Likert scale. Statistical Tests Inter‐reader agreement (IRA) was calculated using intraclass coefficients (ICC). Quantitative analysis of image quality was performed by signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) measurements and compared using Student's t‐testing. Results Image quality, nerve visibility and vascular suppression were significantly higher for Ferumoxtran‐10‐enhanced MRN compared to Gd‐enhanced MRN sequences (p < 0.05). IRA for image quality of nerves was good in Gd‐enhanced and Ferumoxtran‐10 MRN with ICC values of 0.76 and 0.89, respectively. IRA for nerve visibility was good in Gd‐ and Ferumoxtran‐10 enhanced MR neurography (ICC 0.72 and 0.90). Mean SNR was significantly higher in Ferumoxtran‐10‐enhanced MRN for all analyzed structures, while mean CNR was for significantly better for S1 ganglion and femoral nerve in Ferumoxtran‐10‐enhanced MRN (p < 0.05). Data Conclusion Ferumoxtran‐10‐enhanced MRN of the LS plexus showed significantly higher image quality and nerve visibility with better vascular suppression as compared to Gd‐enhanced MRN. Evidence Level 2Technical EfficacyStage 3

Zurich Open Repository and Archive (University of Zurich)
Openalex Percentile: Top 43%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.