Diagnostic accuracy in NSCLC lymph node staging with Total-Body and conventional PET/CT.

Introduction Our aim was to characterize the diagnostic accuracy indices for nodal (N)-staging with [18F]FDG Total-Body (TB) and short-axial field-of-view (SAFOV) PET/CT in non-small cell lung cancer (NSCLC) patients referred for staging or restaging.Methods In this prospective single center cross-over head-to-head comparative study 48 patients underwent [18F]FDG TB and SAFOV PET/CT on the same day. In total 700 lymph node levels (1R/L, 2R/L, 3a/p, 4R/L, 5, 6, 7, 8R/L, 9R/L, 10-14R/L) of 28 patients could be correlated to a composite reference standard (histopathological correlation, imaging after localized or systemic treatment), which allowed determination of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) lesions. Lymph nodes were characterized semi-quantitatively by maximum standardized uptake value (SUVmax), tumor-to-background ratio (TBR), metabolic tumor volume (MTV) and total lesion glycolysis (TLG) leading to threshold for each scanner.Results TB and SAFOV PET/CT showed high diagnostic accuracy indices for patient-based N-staging. Sensitivity and specificity were 86.0% (CI: 77.0-95.0%) and 98.3% (CI: 97.3-99.3%) for TB; 77.2% (CI: 66.3-88.1%) and 97.4% (CI: 96.1-98.6%) for SAFOV PET. Positive predictive value was higher for TB (81.7%, CI: 71.9-91.5%) compared to SAFOV PET (72.1%, CI: 60.9-83.4%). However, this finding was not statistically significant (p = 0.08). Negative predictive values for TB (98.6%, CI: 97.9-99.6%) and SAFOV PET/CT (98.0%, CI: 96.9-99.1%) were comparable. Overall, NSCLC N-staging was affected in six cases on SAFOV and only in one case on TB PET/CT. Semi-quantitative analysis revealed a threshold of SUVmax 3.0 to detect TP lesions on both scanners. However, TBR, MTV and TLG thresholds were lower on TB compared to SAFOV PET (TBR: 1.2 vs. 1.7, MTV: 0.5 ml vs. 1.0 ml and TLG: 1.0 ml vs. 3.0 ml).Conclusion TB and SAFOV PET/CT showed high diagnostic accuracy indices for N-staging in NSCLC patients. Sensitivity and PPV on TB PET/CT were slightly higher, compared to SAFOV PET/CT without statistical significance. However, TB PET/CT showed lower rate of incorrect N-staging and lower semi-quantitative thresholds for the detection positive mediastinal lymph nodes. Therefore, TB PET/CT might be advantageous in detecting small and low [18F]FDG-avidity mediastinal lymph node metastases in NSCLC patients.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-04-16
DOI
https://doi.org/10.48620/87324
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic accuracy in NSCLC lymph node staging with Total-Body and conventional PET/CT.

Open Access CRIS of the University of Bern
Lung Cancer Diagnosis and Treatment
article

Diagnostic accuracy in NSCLC lymph node staging with Total-Body and conventional PET/CT.

article en

Abstract

Introduction Our aim was to characterize the diagnostic accuracy indices for nodal (N)-staging with [18F]FDG Total-Body (TB) and short-axial field-of-view (SAFOV) PET/CT in non-small cell lung cancer (NSCLC) patients referred for staging or restaging.Methods In this prospective single center cross-over head-to-head comparative study 48 patients underwent [18F]FDG TB and SAFOV PET/CT on the same day. In total 700 lymph node levels (1R/L, 2R/L, 3a/p, 4R/L, 5, 6, 7, 8R/L, 9R/L, 10-14R/L) of 28 patients could be correlated to a composite reference standard (histopathological correlation, imaging after localized or systemic treatment), which allowed determination of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) lesions. Lymph nodes were characterized semi-quantitatively by maximum standardized uptake value (SUVmax), tumor-to-background ratio (TBR), metabolic tumor volume (MTV) and total lesion glycolysis (TLG) leading to threshold for each scanner.Results TB and SAFOV PET/CT showed high diagnostic accuracy indices for patient-based N-staging. Sensitivity and specificity were 86.0% (CI: 77.0-95.0%) and 98.3% (CI: 97.3-99.3%) for TB; 77.2% (CI: 66.3-88.1%) and 97.4% (CI: 96.1-98.6%) for SAFOV PET. Positive predictive value was higher for TB (81.7%, CI: 71.9-91.5%) compared to SAFOV PET (72.1%, CI: 60.9-83.4%). However, this finding was not statistically significant (p = 0.08). Negative predictive values for TB (98.6%, CI: 97.9-99.6%) and SAFOV PET/CT (98.0%, CI: 96.9-99.1%) were comparable. Overall, NSCLC N-staging was affected in six cases on SAFOV and only in one case on TB PET/CT. Semi-quantitative analysis revealed a threshold of SUVmax 3.0 to detect TP lesions on both scanners. However, TBR, MTV and TLG thresholds were lower on TB compared to SAFOV PET (TBR: 1.2 vs. 1.7, MTV: 0.5 ml vs. 1.0 ml and TLG: 1.0 ml vs. 3.0 ml).Conclusion TB and SAFOV PET/CT showed high diagnostic accuracy indices for N-staging in NSCLC patients. Sensitivity and PPV on TB PET/CT were slightly higher, compared to SAFOV PET/CT without statistical significance. However, TB PET/CT showed lower rate of incorrect N-staging and lower semi-quantitative thresholds for the detection positive mediastinal lymph nodes. Therefore, TB PET/CT might be advantageous in detecting small and low [18F]FDG-avidity mediastinal lymph node metastases in NSCLC patients.

Open Access CRIS of the University of Bern
Good health and well-being
Openalex Percentile: Top 39%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Diagnostic accuracy in NSCLC lymph node staging with Total-Body and conventional PET/CT. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS