Long-Term Clinical and Radiographic Outcomes of Hydrophilic Implants: A 10-Year Study in a Specialist Private Practice.

Aim To report the 10-year clinical and radiographic outcomes of implants placed in grafted (GBR) and non-grafted (no-GBR) sites in a Swiss specialist private practice using hydrophilic implants with a low surface roughness flange. Methods Fifty consecutively enrolled patients received 159 hydrophilic implants with a low surface roughness flange. A first re-evaluation was performed 1 year after delivery of restoration (T1). An additional examination was performed at the 10-year follow-up (T2) including the assessment of clinical (i.e., periodontal/peri-implant pockets probing depths (PPD) (mm), full-mouth bleeding score (%), implant survival rate, mid-buccal keratinized mucosa (KM) width in mm, and peri-implant phenotype), and radiographic (i.e., marginal bone level change [ΔMBL]) outcomes. Biological, mechanical and technical complications were also recorded. Results Out of the initial cohort, 22 patients (9/40.9% male and 13/59% female) and 63 implants (47 with GBR, 16 without GBR), could be re-examined at T2. Overall, ΔMBL (T2-T1) was -0.56 ± 0.96 mm. In the GBR group, ΔMBL were significantly higher at the distal sites compared to the no-GBR group (-0.75 ± 1.17 mm vs. -0.12 ± 1.29 mm, p = 0.045), however, in the GBR group MBL started at a higher level at T1 but were similar with the no-GBR group at T2. Implant survival was 100% with only very few technical complications (6.3%). Mean PPD amounted to 3.84 ± 1.00 mm with significantly higher values in the GBR group (3.98 ± 1.08 mm vs. 3.45 ± 0.60 mm; p = 0.016). Nineteen implants (30.1%) were diagnosed with peri-implant health while 44 (69.9%) presented with peri-implant mucositis. Conclusion Within the limitations of this study, favorable clinical and radiographic conditions were recorded around hydrophilic implants with a low surface roughness flange placed in pristine and augmented bone after 10 years in function.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-12-11
DOI
https://doi.org/10.48620/77418
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-Term Clinical and Radiographic Outcomes of Hydrophilic Implants: A 10-Year Study in a Specialist Private Practice.

Open Access CRIS of the University of Bern
Dental Implant Techniques and Outcomes
article

Long-Term Clinical and Radiographic Outcomes of Hydrophilic Implants: A 10-Year Study in a Specialist Private Practice.

article en

Abstract

Aim To report the 10-year clinical and radiographic outcomes of implants placed in grafted (GBR) and non-grafted (no-GBR) sites in a Swiss specialist private practice using hydrophilic implants with a low surface roughness flange. Methods Fifty consecutively enrolled patients received 159 hydrophilic implants with a low surface roughness flange. A first re-evaluation was performed 1 year after delivery of restoration (T1). An additional examination was performed at the 10-year follow-up (T2) including the assessment of clinical (i.e., periodontal/peri-implant pockets probing depths (PPD) (mm), full-mouth bleeding score (%), implant survival rate, mid-buccal keratinized mucosa (KM) width in mm, and peri-implant phenotype), and radiographic (i.e., marginal bone level change [ΔMBL]) outcomes. Biological, mechanical and technical complications were also recorded. Results Out of the initial cohort, 22 patients (9/40.9% male and 13/59% female) and 63 implants (47 with GBR, 16 without GBR), could be re-examined at T2. Overall, ΔMBL (T2-T1) was -0.56 ± 0.96 mm. In the GBR group, ΔMBL were significantly higher at the distal sites compared to the no-GBR group (-0.75 ± 1.17 mm vs. -0.12 ± 1.29 mm, p = 0.045), however, in the GBR group MBL started at a higher level at T1 but were similar with the no-GBR group at T2. Implant survival was 100% with only very few technical complications (6.3%). Mean PPD amounted to 3.84 ± 1.00 mm with significantly higher values in the GBR group (3.98 ± 1.08 mm vs. 3.45 ± 0.60 mm; p = 0.016). Nineteen implants (30.1%) were diagnosed with peri-implant health while 44 (69.9%) presented with peri-implant mucositis. Conclusion Within the limitations of this study, favorable clinical and radiographic conditions were recorded around hydrophilic implants with a low surface roughness flange placed in pristine and augmented bone after 10 years in function.

Open Access CRIS of the University of Bern
University of Dental Medicine (MM)
Partnerships for the goals
Openalex Percentile: Top 57%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.