Reproducibility and Reliability of Intraoral Scanners for Evaluating Peri-Implant Tissues and Implant-Supported Prostheses: A Cross-Sectional Study.

Objective To assess the reproducibility and reliability of the pink (PES) and white esthetic scores (WES) using digital images and the intra- and inter-examiner agreement among different clinical backgrounds and assessment methods.Material And Methods Standardized intraoral images were obtained from adult subjects with an implant-supported single-tooth fixed dental prosthesis located in the maxillary esthetic zone using a digital camera and a true-color intraoral scanner. According to the PES and WES criteria, the images were evaluated by 20 calibrated evaluators, 5 prosthodontists, 5 periodontists, 5 undergraduates, and 5 oral surgeons.Results The total number of individual PES and WES was 12600 and 9000, respectively. Similar PES and WES values were obtained with the intraoral scanner compared to the digital camera. Intra- and inter-rater variations were observed between and within evaluators' clinical backgrounds, with periodontists showing consistently lower mean PES and WES. The intraclass correlation coefficient ranges between 0.41 to 0.61 for the PES and 0.42 to 0.69 for the WES, resulting in fair to good agreement in both digital methods.Conclusion The digital assessment of the peri-implant tissues and implant-supported prostheses utilizing images provided by an intraoral scanner offers a reproducible and reliable digital method comparable with the digital camera.Clinical Significance This study highlights the reliability and reproducibility of using intraoral scanners for evaluating peri-implant tissues and implant-supported prostheses. The findings suggest that intraoral scanners are a viable digital alternative to traditional digital imaging for these assessments. However, the observed intra- and inter-rater variations in pink and white esthetic scores, according to the clinical background of evaluators, emphasize the need for caution when interpreting these values in clinical decision-making and research.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-01-22
DOI
https://doi.org/10.48620/84835
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reproducibility and Reliability of Intraoral Scanners for Evaluating Peri-Implant Tissues and Implant-Supported Prostheses: A Cross-Sectional Study.

Open Access CRIS of the University of Bern
Dental materials and restorations
article

Reproducibility and Reliability of Intraoral Scanners for Evaluating Peri-Implant Tissues and Implant-Supported Prostheses: A Cross-Sectional Study.

article en

Abstract

Objective To assess the reproducibility and reliability of the pink (PES) and white esthetic scores (WES) using digital images and the intra- and inter-examiner agreement among different clinical backgrounds and assessment methods.Material And Methods Standardized intraoral images were obtained from adult subjects with an implant-supported single-tooth fixed dental prosthesis located in the maxillary esthetic zone using a digital camera and a true-color intraoral scanner. According to the PES and WES criteria, the images were evaluated by 20 calibrated evaluators, 5 prosthodontists, 5 periodontists, 5 undergraduates, and 5 oral surgeons.Results The total number of individual PES and WES was 12600 and 9000, respectively. Similar PES and WES values were obtained with the intraoral scanner compared to the digital camera. Intra- and inter-rater variations were observed between and within evaluators' clinical backgrounds, with periodontists showing consistently lower mean PES and WES. The intraclass correlation coefficient ranges between 0.41 to 0.61 for the PES and 0.42 to 0.69 for the WES, resulting in fair to good agreement in both digital methods.Conclusion The digital assessment of the peri-implant tissues and implant-supported prostheses utilizing images provided by an intraoral scanner offers a reproducible and reliable digital method comparable with the digital camera.Clinical Significance This study highlights the reliability and reproducibility of using intraoral scanners for evaluating peri-implant tissues and implant-supported prostheses. The findings suggest that intraoral scanners are a viable digital alternative to traditional digital imaging for these assessments. However, the observed intra- and inter-rater variations in pink and white esthetic scores, according to the clinical background of evaluators, emphasize the need for caution when interpreting these values in clinical decision-making and research.

Open Access CRIS of the University of Bern
University of Dental Medicine (MM), Stomatology Hospital (CN)
Peace, Justice and strong institutions
Openalex Percentile: Top 48%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reproducibility and Reliability of Intraoral Scanners for Evaluating Peri-Implant Tissues and Implant-Supported Prostheses: A Cross-Sectional Study. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS