A dosimetrically motivated pathfinding approach for non-isocentric dynamic trajectory radiotherapy.

Non-isocentric dynamic trajectory radiotherapy (DTRT) involves dynamic table translations in synchrony with intensity modulation and dynamic gantry, table, and/or collimator rotation. This work aims to develop and evaluate a novel dosimetrically motivated path determination technique for non-isocentric DTRT.The path determination considers all available beam directions, given on a user-specified grid of gantry angle, table angle, and longitudinal, vertical, and lateral table position. Additionally, the source-to-target distance of all beam directions can be extended by moving the table away from the gantry along the central beam axis to increase the collision-free space. The path determination uses a column generation algorithm to iteratively add beam directions to paths until a user-defined total path length is reached. A subsequent direct aperture optimization of the intensity modulation along the paths creates deliverable plans. Non-isocentric DTRT plans using the path determination and using a manual path setup were created for a craniospinal and a spinal irradiation case. Furthermore, VMAT, isocentric DTRT, and non-isocentric DTRT plans are created for a breast, head and neck (H&N), and esophagus case. Additionally, a HyperArc plan is created for the H&N case. The plans are compared in terms of the dosimetric treatment plan quality and estimated delivery time.For the craniospinal and spinal irradiation case, using path determination results in dose distributions with improved conformity but a slightly worse target homogeneity compared to manual path setup. The non-isocentric DTRT plans maintained target coverage while reducing the mean dose to organs-at-risk on average by 1.7 Gy (breast), 1.0 Gy (H&N), and 1.6 Gy (esophagus) compared to the VMAT plans and by 0.8 Gy (breast), 0.6 Gy (H&N), and 0.8 Gy (esophagus) compared to the isocentric DTRT plans.A general dosimetrically motivated path determination applicable to non-isocentric DTRT plans is successfully developed, further advancing the treatment planning for non-isocentric DTRT.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-09-12
DOI
https://doi.org/10.48620/8356
Primary Topic
Silicon Carbide Semiconductor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A dosimetrically motivated pathfinding approach for non-isocentric dynamic trajectory radiotherapy.

Open Access CRIS of the University of Bern
Silicon Carbide Semiconductor Technologies
article

A dosimetrically motivated pathfinding approach for non-isocentric dynamic trajectory radiotherapy.

article en

Abstract

Non-isocentric dynamic trajectory radiotherapy (DTRT) involves dynamic table translations in synchrony with intensity modulation and dynamic gantry, table, and/or collimator rotation. This work aims to develop and evaluate a novel dosimetrically motivated path determination technique for non-isocentric DTRT.The path determination considers all available beam directions, given on a user-specified grid of gantry angle, table angle, and longitudinal, vertical, and lateral table position. Additionally, the source-to-target distance of all beam directions can be extended by moving the table away from the gantry along the central beam axis to increase the collision-free space. The path determination uses a column generation algorithm to iteratively add beam directions to paths until a user-defined total path length is reached. A subsequent direct aperture optimization of the intensity modulation along the paths creates deliverable plans. Non-isocentric DTRT plans using the path determination and using a manual path setup were created for a craniospinal and a spinal irradiation case. Furthermore, VMAT, isocentric DTRT, and non-isocentric DTRT plans are created for a breast, head and neck (H&N), and esophagus case. Additionally, a HyperArc plan is created for the H&N case. The plans are compared in terms of the dosimetric treatment plan quality and estimated delivery time.For the craniospinal and spinal irradiation case, using path determination results in dose distributions with improved conformity but a slightly worse target homogeneity compared to manual path setup. The non-isocentric DTRT plans maintained target coverage while reducing the mean dose to organs-at-risk on average by 1.7 Gy (breast), 1.0 Gy (H&N), and 1.6 Gy (esophagus) compared to the VMAT plans and by 0.8 Gy (breast), 0.6 Gy (H&N), and 0.8 Gy (esophagus) compared to the isocentric DTRT plans.A general dosimetrically motivated path determination applicable to non-isocentric DTRT plans is successfully developed, further advancing the treatment planning for non-isocentric DTRT.

Open Access CRIS of the University of Bern
HP Family Medical Clinic (US)
Openalex Percentile: Top 70%
Silicon Carbide Semiconductor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.