Influence of the Vertek aiming device on the surgical accuracy of computer-assisted drilling of the equine distal sesamoid bone - An experimental cadaveric study

To determine the effect of the Vertek aiming device (VAD) on the surgical accuracy of navigated drilling of the distal sesamoid bone (DSB). Study design: Experimental cadaveric study. Sample population: A total of 30 paired equine cadaveric limbs from 15 horses. Methods: Each specimen was placed in a purpose‐built frame (PBF). Preoperative cone beam computed tomography (CBCT) images were acquired with an imaging unit coupled with a surgical navigation system. In the DSB of each specimen, a 4.5 mm glide hole and a 3.2 mm thread hole were drilled under navigation guidance, to simulate drilling for the repair of a mid‐sagittal DSB fracture. In the VAD group navigated drilling was assisted by using the VAD. In the free‐hand drilling group navigated drilling was performed without the VAD. Pre‐and postoperative CBCT scans were merged and surgical accuracy aberrations (SAA) between the planned drill corridor and the created bone tunnel were measured. Descriptive statistics and repeated‐measures analyses of variance (rep.‐meas. ANOVA) were performed to compare SAA measurements between the study groups. Results: The SAA measurements ranged from 0 to 2.9 mm in the free‐hand group and from 0 to 2.8 mm in the VAD group. The median overall SAA was lower in the VAD group than in the free‐hand navigated group (0.6 mm ± [0.5–0.7] vs. 0.8 mm ± [0.7–1], rep.‐meas. ANOVA = .007). Conclusion: The additional use of the VAD in the described set‐up for navigated drilling significantly improved surgical accuracy. Clinical significance: The combined use of the VAD and PBF may help improve surgical accuracy in navigated lag screw repair of DSB fractures.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-09-27
DOI
https://doi.org/10.48620/74910
Primary Topic
Veterinary Equine Medical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of the Vertek aiming device on the surgical accuracy of computer-assisted drilling of the equine distal sesamoid bone - An experimental cadaveric study

Open Access CRIS of the University of Bern
Veterinary Equine Medical Research
article

Influence of the Vertek aiming device on the surgical accuracy of computer-assisted drilling of the equine distal sesamoid bone - An experimental cadaveric study

article en

Abstract

To determine the effect of the Vertek aiming device (VAD) on the surgical accuracy of navigated drilling of the distal sesamoid bone (DSB). Study design: Experimental cadaveric study. Sample population: A total of 30 paired equine cadaveric limbs from 15 horses. Methods: Each specimen was placed in a purpose‐built frame (PBF). Preoperative cone beam computed tomography (CBCT) images were acquired with an imaging unit coupled with a surgical navigation system. In the DSB of each specimen, a 4.5 mm glide hole and a 3.2 mm thread hole were drilled under navigation guidance, to simulate drilling for the repair of a mid‐sagittal DSB fracture. In the VAD group navigated drilling was assisted by using the VAD. In the free‐hand drilling group navigated drilling was performed without the VAD. Pre‐and postoperative CBCT scans were merged and surgical accuracy aberrations (SAA) between the planned drill corridor and the created bone tunnel were measured. Descriptive statistics and repeated‐measures analyses of variance (rep.‐meas. ANOVA) were performed to compare SAA measurements between the study groups. Results: The SAA measurements ranged from 0 to 2.9 mm in the free‐hand group and from 0 to 2.8 mm in the VAD group. The median overall SAA was lower in the VAD group than in the free‐hand navigated group (0.6 mm ± [0.5–0.7] vs. 0.8 mm ± [0.7–1], rep.‐meas. ANOVA = .007). Conclusion: The additional use of the VAD in the described set‐up for navigated drilling significantly improved surgical accuracy. Clinical significance: The combined use of the VAD and PBF may help improve surgical accuracy in navigated lag screw repair of DSB fractures.

Open Access CRIS of the University of Bern
Swiss Institute of Equine Medicine (CH), Public Health Institute (US), Faculty of Public Health (GB), Clinical Research Management (US)
Openalex Percentile: Top 60%
Veterinary Equine Medical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of the Vertek aiming device on the surgical accuracy of computer-assisted drilling of the equine distal sesamoid bone - An experimental cadaveric study · Open Access CRIS of the University of Bern (2024) | TGRS Research Map | TGRS