Is Long-Axial-Field-of-View PET/CT Cost-Effective? An International Health-Economic Analysis.

Our aim is to assess the cost-effectiveness of long-axial-field-of-view (LAFOV) versus short-axial FOV (SAFOV) PET/CT systems using international data. Methods: Our model compares equipment and operational costs for a PET/CT center and investigates the effect of camera choice (SAFOV vs. LAFOV) and operational models. Variables include scanner, personnel, radiopharmaceuticals, and operational costs. Economic performance was measured as cost per scan per patient, the total maximum number of scans possible, and the incremental cost-effectiveness ratio. The willingness-to-pay threshold (WTPT) was taken as the cost of a PET/CT scan using the baseline scenario. Radiopharmaceutical requirements, radiation dose to staff and patients, and patient time were modeled. Results: An LAFOV system can examine as many patients per day (n = 36) as 2 SAFOV systems but requires fewer technologists (4.5 LAFOV vs. 6.8 SAFOV full-time equivalents) and lower activity (12.5 vs. 35.6 GBq/d), resulting in lower personnel doses (0.9 vs. 2.0 mSv/y). For all countries, LAFOV resulted in lowest per-patient scan costs. The most cost-ineffective method was the use of extended hours. Incremental cost-effectiveness ratio analysis strongly favored LAFOV for all countries, including low-income economies, with WTPT met for all jurisdictions. Net monetary benefit was highest for LAFOV. The minimum number of patients needed to meet WTPT for LAFOV was lowest in lower-income countries, suggesting that high throughput or high per-procedure income is not a prerequisite for cost-effective LAFOV usage. Conclusion: LAFOV was shown to facilitate higher patient throughput at lower per-patient and total lifetime operational costs and with lower radiopharmaceutical requirements. These data suggest that LAFOV systems are not just suited to well-resourced academic centers but also are an economically attractive solution for community and resource-limited settings.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-05-09
DOI
https://doi.org/10.48620/87916
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Is Long-Axial-Field-of-View PET/CT Cost-Effective? An International Health-Economic Analysis.

Open Access CRIS of the University of Bern
Medical Imaging Techniques and Applications
article

Is Long-Axial-Field-of-View PET/CT Cost-Effective? An International Health-Economic Analysis.

article en

Abstract

Our aim is to assess the cost-effectiveness of long-axial-field-of-view (LAFOV) versus short-axial FOV (SAFOV) PET/CT systems using international data. Methods: Our model compares equipment and operational costs for a PET/CT center and investigates the effect of camera choice (SAFOV vs. LAFOV) and operational models. Variables include scanner, personnel, radiopharmaceuticals, and operational costs. Economic performance was measured as cost per scan per patient, the total maximum number of scans possible, and the incremental cost-effectiveness ratio. The willingness-to-pay threshold (WTPT) was taken as the cost of a PET/CT scan using the baseline scenario. Radiopharmaceutical requirements, radiation dose to staff and patients, and patient time were modeled. Results: An LAFOV system can examine as many patients per day (n = 36) as 2 SAFOV systems but requires fewer technologists (4.5 LAFOV vs. 6.8 SAFOV full-time equivalents) and lower activity (12.5 vs. 35.6 GBq/d), resulting in lower personnel doses (0.9 vs. 2.0 mSv/y). For all countries, LAFOV resulted in lowest per-patient scan costs. The most cost-ineffective method was the use of extended hours. Incremental cost-effectiveness ratio analysis strongly favored LAFOV for all countries, including low-income economies, with WTPT met for all jurisdictions. Net monetary benefit was highest for LAFOV. The minimum number of patients needed to meet WTPT for LAFOV was lowest in lower-income countries, suggesting that high throughput or high per-procedure income is not a prerequisite for cost-effective LAFOV usage. Conclusion: LAFOV was shown to facilitate higher patient throughput at lower per-patient and total lifetime operational costs and with lower radiopharmaceutical requirements. These data suggest that LAFOV systems are not just suited to well-resourced academic centers but also are an economically attractive solution for community and resource-limited settings.

Open Access CRIS of the University of Bern
Openalex Percentile: Top 43%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Is Long-Axial-Field-of-View PET/CT Cost-Effective? An International Health-Economic Analysis. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS