Ten-Year Results of the Fitmore Hip Stem with a Focus on Varus/Valgus Alignment and Subsidence-A Retrospective Monocentric Analysis.

Hip arthroplasty is a common elective surgery worldwide, with rising numbers due to demographic changes and an emphasis on maintaining physical activity in the elderly. The development of new implant designs, especially shorter uncemented stems, has contributed to the advancement of minimally invasive implantation techniques. However, the long-term in vivo behaviour of these implants, particularly regarding subsidence, stability, and stress shielding, remains to be fully understood. This retrospective, monocentric cohort study analyses the long-term radiographic outcomes of the first 141 patients who underwent total hip arthroplasty with the Fitmore Hip Stem between June 2007 and December 2008. It focuses on subsidence, stability, varus-valgus alignment, and the influence of patient-related, anatomical, and surgical factors on implant behaviour over a 10-year follow-up period. The average change in varus/valgus alignment was 0.7° into varus and the average subsidence was 1.7 mm over 10 years, with most changes occurring within the first six weeks postoperatively. The varus-valgus alignment and subsidence did not significantly change after the first year, indicating stable osteointegration of the implant. Neither patient factors (gender, age) nor surgical and implant factors (implantation angle, approach, stem family, size, total offset) had a significant influence on the long-term behaviour of the implant. The Fitmore Hip Stem shows highly reliable long-term stability and integration, unaffected by various patient, surgical, and implant factors, as confirmed by excellent register data. Nevertheless, monitoring of this and other new implants should be continued in order to determine implant behaviour, possible weaknesses, and indication limits at an early stage for the benefit of the patient.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-09-20
DOI
https://doi.org/10.48620/76011
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ten-Year Results of the Fitmore Hip Stem with a Focus on Varus/Valgus Alignment and Subsidence-A Retrospective Monocentric Analysis.

Open Access CRIS of the University of Bern
Orthopaedic implants and arthroplasty
article

Ten-Year Results of the Fitmore Hip Stem with a Focus on Varus/Valgus Alignment and Subsidence-A Retrospective Monocentric Analysis.

article en

Abstract

Hip arthroplasty is a common elective surgery worldwide, with rising numbers due to demographic changes and an emphasis on maintaining physical activity in the elderly. The development of new implant designs, especially shorter uncemented stems, has contributed to the advancement of minimally invasive implantation techniques. However, the long-term in vivo behaviour of these implants, particularly regarding subsidence, stability, and stress shielding, remains to be fully understood. This retrospective, monocentric cohort study analyses the long-term radiographic outcomes of the first 141 patients who underwent total hip arthroplasty with the Fitmore Hip Stem between June 2007 and December 2008. It focuses on subsidence, stability, varus-valgus alignment, and the influence of patient-related, anatomical, and surgical factors on implant behaviour over a 10-year follow-up period. The average change in varus/valgus alignment was 0.7° into varus and the average subsidence was 1.7 mm over 10 years, with most changes occurring within the first six weeks postoperatively. The varus-valgus alignment and subsidence did not significantly change after the first year, indicating stable osteointegration of the implant. Neither patient factors (gender, age) nor surgical and implant factors (implantation angle, approach, stem family, size, total offset) had a significant influence on the long-term behaviour of the implant. The Fitmore Hip Stem shows highly reliable long-term stability and integration, unaffected by various patient, surgical, and implant factors, as confirmed by excellent register data. Nevertheless, monitoring of this and other new implants should be continued in order to determine implant behaviour, possible weaknesses, and indication limits at an early stage for the benefit of the patient.

Open Access CRIS of the University of Bern
Gender equality
Openalex Percentile: Top 51%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.