Technical note: An optimized protocol for standard unenhanced whole-body post-mortem Photon Counting CT imaging.

In recent years, Photon-counting detector CT (PCD CT) has emerged as a new and groundbreaking technology in clinical radiology. While clinical research and practical applications of PCD-CT are constantly evolving, it has not yet been integrated into post-mortem CT (PMCT) imaging. Documented research into the potential applications of PCD CT in the field of post-mortem human forensic pathology and anatomical pathology is scarce in literature. This is despite the fact that PCD CT shows promise in expanding PMCT imaging diagnostic due to features such as ultra-high resolution and intrinsic spectral multienergy imaging. The authors have recently started scanning forensic corpses with a PCD CT to explore its possibilities and limits in the post-mortem field. In this technical note, the PCD CT acquisition and reconstruction parameters that resulted in excellent image quality in terms of noise and contrast for a slice thickness up to 0.2 mm in unenhanced whole-body examinations are presented.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-12-10
DOI
https://doi.org/10.48620/77343
Primary Topic
Autopsy Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Technical note: An optimized protocol for standard unenhanced whole-body post-mortem Photon Counting CT imaging.

Open Access CRIS of the University of Bern
Autopsy Techniques and Outcomes
article

Technical note: An optimized protocol for standard unenhanced whole-body post-mortem Photon Counting CT imaging.

article en

Abstract

In recent years, Photon-counting detector CT (PCD CT) has emerged as a new and groundbreaking technology in clinical radiology. While clinical research and practical applications of PCD-CT are constantly evolving, it has not yet been integrated into post-mortem CT (PMCT) imaging. Documented research into the potential applications of PCD CT in the field of post-mortem human forensic pathology and anatomical pathology is scarce in literature. This is despite the fact that PCD CT shows promise in expanding PMCT imaging diagnostic due to features such as ultra-high resolution and intrinsic spectral multienergy imaging. The authors have recently started scanning forensic corpses with a PCD CT to explore its possibilities and limits in the post-mortem field. In this technical note, the PCD CT acquisition and reconstruction parameters that resulted in excellent image quality in terms of noise and contrast for a slice thickness up to 0.2 mm in unenhanced whole-body examinations are presented.

Open Access CRIS of the University of Bern
Society of Interventional Radiology (US), Institute of Forensic Science (CN)
Openalex Percentile: Top 54%
Autopsy Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Technical note: An optimized protocol for standard unenhanced whole-body post-mortem Photon Counting CT imaging. · Open Access CRIS of the University of Bern (2024) | TGRS Research Map | TGRS