Experimental and computational evaluation of knee implant wear and creep under in vivo and ISO boundary conditions

Background Experimental knee implant wear testing according to ISO 14243 is a standard procedure, but it inherently possesses limitations for preclinical evaluations due to extended testing periods and costly infrastructure. In an effort to overcome these limitations, we hereby develop and experimentally validate a finite-element (FE)-based algorithm, including a novel cross-shear and contact pressure dependent wear and creep model, and apply it towards understanding the sensitivity of wear outcomes to the applied boundary conditions. Methods Specifically, we investigated the application of in vivo data for level walking from the publicly available “Stan” data set, which contains single representative tibiofemoral loads and kinematics derived from in vivo measurements of six subjects, and compared wear outcomes against those obtained using the ISO standard boundary conditions. To provide validation of the numerical models, this comparison was reproduced experimentally on a six-station knee wear simulator over 5 million cycles, testing the same implant Stan’s data was obtained from. Results Experimental implementation of Stan’s boundary conditions in displacement control resulted in approximately three times higher wear rates (4.4 vs. 1.6 mm3 per million cycles) and a more anterior wear pattern compared to the ISO standard in force control. While a force-controlled ISO FE model was unable to reproduce the bench test kinematics, and thus wear rate, due to a necessarily simplified representation of the simulator machine, similar but displacement-controlled FE models accurately predicted the laboratory wear tests for both ISO and Stan boundary conditions. The credibility of the in silico wear and creep model was further established per the ASME V&V-40 standard. Conclusions The FE wear model is suitable for supporting future patient-specific models and development of novel implant designs. Incorporating the Stan data set alongside ISO boundary conditions emphasized the value of using measured kinematics in displacement control for reliably replicating in vivo joint mechanics in wear simulation. Future work should focus on expanding the range of daily activities simulated and addressing model sensitivity to contact mechanics to further enhance predictive accuracy.

Publication Details

Journal
Repository for Publications and Research Data (ETH Zurich)
Published
2024-12-23
DOI
https://doi.org/10.3929/ethz-b-000713377
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and computational evaluation of knee implant wear and creep under in vivo and ISO boundary conditions

Repository for Publications and Research Data (ETH Zurich)
Total Knee Arthroplasty Outcomes
article

Experimental and computational evaluation of knee implant wear and creep under in vivo and ISO boundary conditions

article en

Abstract

Background Experimental knee implant wear testing according to ISO 14243 is a standard procedure, but it inherently possesses limitations for preclinical evaluations due to extended testing periods and costly infrastructure. In an effort to overcome these limitations, we hereby develop and experimentally validate a finite-element (FE)-based algorithm, including a novel cross-shear and contact pressure dependent wear and creep model, and apply it towards understanding the sensitivity of wear outcomes to the applied boundary conditions. Methods Specifically, we investigated the application of in vivo data for level walking from the publicly available “Stan” data set, which contains single representative tibiofemoral loads and kinematics derived from in vivo measurements of six subjects, and compared wear outcomes against those obtained using the ISO standard boundary conditions. To provide validation of the numerical models, this comparison was reproduced experimentally on a six-station knee wear simulator over 5 million cycles, testing the same implant Stan’s data was obtained from. Results Experimental implementation of Stan’s boundary conditions in displacement control resulted in approximately three times higher wear rates (4.4 vs. 1.6 mm3 per million cycles) and a more anterior wear pattern compared to the ISO standard in force control. While a force-controlled ISO FE model was unable to reproduce the bench test kinematics, and thus wear rate, due to a necessarily simplified representation of the simulator machine, similar but displacement-controlled FE models accurately predicted the laboratory wear tests for both ISO and Stan boundary conditions. The credibility of the in silico wear and creep model was further established per the ASME V&V-40 standard. Conclusions The FE wear model is suitable for supporting future patient-specific models and development of novel implant designs. Incorporating the Stan data set alongside ISO boundary conditions emphasized the value of using measured kinematics in displacement control for reliably replicating in vivo joint mechanics in wear simulation. Future work should focus on expanding the range of daily activities simulated and addressing model sensitivity to contact mechanics to further enhance predictive accuracy.

Repository for Publications and Research Data (ETH Zurich)
Industry, innovation and infrastructure
Openalex Percentile: Top 51%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.