Interlaboratory study of the operational stability of automated sorption balances

Automated sorption balances are widely used for characterizing the interaction of water vapor with hygroscopic materials. These instruments provide an efficient way to collect sorption isotherm data and kinetic data. A typical method for defining equilibrium after a step change in relative humidity (RH) is using a particular threshold value for the rate of change in mass with time. Recent studies indicate that commonly used threshold values yield substantial errors and that further measurements are needed at extended hold times as a basis to assess the accuracy of abbreviated equilibration criteria. However, the mass measurement accuracy at extended times depends on the operational stability of the instrument. Published data on the stability of automated sorption balances are rare. An interlaboratory study was undertaken to investigate equilibration criteria for automated sorption balances. This paper focuses on the mass, temperature, and RH stability and includes data from 25 laboratories throughout the world. An initial target for instrument mass stability was met on the first attempt in many cases, but several instruments were found to have unexpectedly large instabilities. The sources of these instabilities were investigated and greatly reduced. This paper highlights the importance of verifying operational mass stability of automated sorption balances, gives a method to perform stability checks, and provides guidance on identifying and correcting common sources of mass instability.

Publication Details

Journal
Repository for Publications and Research Data (ETH Zurich)
Published
2024-10-01
DOI
https://doi.org/10.3929/ethz-b-000670420
Primary Topic
Engineering and Material Science Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interlaboratory study of the operational stability of automated sorption balances

Repository for Publications and Research Data (ETH Zurich)
Engineering and Material Science Research
article

Interlaboratory study of the operational stability of automated sorption balances

article en

Abstract

Automated sorption balances are widely used for characterizing the interaction of water vapor with hygroscopic materials. These instruments provide an efficient way to collect sorption isotherm data and kinetic data. A typical method for defining equilibrium after a step change in relative humidity (RH) is using a particular threshold value for the rate of change in mass with time. Recent studies indicate that commonly used threshold values yield substantial errors and that further measurements are needed at extended hold times as a basis to assess the accuracy of abbreviated equilibration criteria. However, the mass measurement accuracy at extended times depends on the operational stability of the instrument. Published data on the stability of automated sorption balances are rare. An interlaboratory study was undertaken to investigate equilibration criteria for automated sorption balances. This paper focuses on the mass, temperature, and RH stability and includes data from 25 laboratories throughout the world. An initial target for instrument mass stability was met on the first attempt in many cases, but several instruments were found to have unexpectedly large instabilities. The sources of these instabilities were investigated and greatly reduced. This paper highlights the importance of verifying operational mass stability of automated sorption balances, gives a method to perform stability checks, and provides guidance on identifying and correcting common sources of mass instability.

Repository for Publications and Research Data (ETH Zurich)
Clean water and sanitation
Openalex Percentile: Top 45%
Engineering and Material Science Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.