Use of radio frequency identification technology to enhance the traceability of bull semen does not affect sperm motility or nonreturn rates

Advancements in radio frequency identification (RFID) technology offer potential for improving traceability during artificial insemination, yet the influence of different radio wave frequencies on semen quality and fertility remains unclear. The size of the low-frequency (LF; 134.2 kHz) chips is convenient for handling in the barn, whereas technical characteristics of high-frequency (HF; 13.56 MHz) chips allow its insertion in the straw for field traceability. Therefore, this study evaluated the effects of LF and HF RFID chips on bovine sperm motility and fertility outcomes. The LF chips (full duplex-B; 8 or 12 mm diameter) were assessed for their effect on fresh sperm motility in vitro and fertility in vivo over a 3-d period. Sperm motility parameters, analyzed by a trained andrologist and via computer-assisted semen analysis (CASA), showed no significant differences between treatments and controls. Field inseminations (n = 49,473) revealed no overall effect of LF chip exposure on the56-d nonreturn rate (NRR), although bull- and parity-specific variations were observed. The HF RFID chips, inserted into semen straws, were tested alone and in combination with LF chips. Post-thaw CASA analysis indicated that exposure to HF chips, either alone or following LF chip exposure, had no effect on sperm quality and motility parameters. Similarly, there was no effect of HF chips on 56-d NRR in field fertility evaluations (n = 1,256 inseminations). The integration of LF and HF chips with a bespoke database system, connecting semen processing to bull ear tag information, demonstrated enhanced trace-ability and improved accuracy in semen labeling. These findings support the feasibility of RFID technology for enhancing traceability in bovine reproduction systems while maintaining sperm motility and fertility

Institutions

Publication Details

Journal
University of Limerick Institutional Repository (University of Limerick)
Published
2025-01-01
DOI
https://doi.org/10.34961/researchrepository-ul.29352368
Primary Topic
Sperm and Testicular Function
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of radio frequency identification technology to enhance the traceability of bull semen does not affect sperm motility or nonreturn rates

University of Limerick Institutional Repository (University of Limerick)
Sperm and Testicular Function
article

Use of radio frequency identification technology to enhance the traceability of bull semen does not affect sperm motility or nonreturn rates

article en

Abstract

Advancements in radio frequency identification (RFID) technology offer potential for improving traceability during artificial insemination, yet the influence of different radio wave frequencies on semen quality and fertility remains unclear. The size of the low-frequency (LF; 134.2 kHz) chips is convenient for handling in the barn, whereas technical characteristics of high-frequency (HF; 13.56 MHz) chips allow its insertion in the straw for field traceability. Therefore, this study evaluated the effects of LF and HF RFID chips on bovine sperm motility and fertility outcomes. The LF chips (full duplex-B; 8 or 12 mm diameter) were assessed for their effect on fresh sperm motility in vitro and fertility in vivo over a 3-d period. Sperm motility parameters, analyzed by a trained andrologist and via computer-assisted semen analysis (CASA), showed no significant differences between treatments and controls. Field inseminations (n = 49,473) revealed no overall effect of LF chip exposure on the56-d nonreturn rate (NRR), although bull- and parity-specific variations were observed. The HF RFID chips, inserted into semen straws, were tested alone and in combination with LF chips. Post-thaw CASA analysis indicated that exposure to HF chips, either alone or following LF chip exposure, had no effect on sperm quality and motility parameters. Similarly, there was no effect of HF chips on 56-d NRR in field fertility evaluations (n = 1,256 inseminations). The integration of LF and HF chips with a bespoke database system, connecting semen processing to bull ear tag information, demonstrated enhanced trace-ability and improved accuracy in semen labeling. These findings support the feasibility of RFID technology for enhancing traceability in bovine reproduction systems while maintaining sperm motility and fertility

University of Limerick Institutional Repository (University of Limerick)
University of Limerick (IE)
Openalex Percentile: Top 47%
Sperm and Testicular Function
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.