Maintaining a resonance condition of an rf spin rotator through a feedback loop in a storage ring

This paper presents the successful application of a phase-lock feedback system to maintain the resonance condition of a radio frequency (rf) spin rotator (specifically, an rf Wien filter) with respect to a 120 kHz spin precession in the Cooler Synchrotron (COSY) storage ring. Real-time monitoring of the spin precession and the rf Wien filter signal allows the relative phase between the two to be stabilized at an arbitrary setpoint. The feedback system compensates for deviations in the relative phase by adjusting the frequency and/or phase of the rf device as needed. With this method, a variation in the phase relative to the demanded value with a standard deviation of 𝜎Δ⁢𝜑≈0.2 rad could be achieved. The system was implemented in two runs aiming at a first direct measurement of the deuteron electric dipole moment in 2018 and 2021. In addition, the difference between a single-bunch beam affected by the spin rotator and a two-bunch system in which only one bunch is exposed to the spin rotator fields is discussed. Both methods have been used during these beam times. The ability to keep the spin precession and the rf fields synchronized is crucial for future investigations of electric dipole moments of charged particles using storage rings.

Institutions

Publication Details

Journal
JuSER Publikationsportal
Published
2025-01-01
DOI
https://doi.org/10.34734/fzj-2025-02878
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Maintaining a resonance condition of an rf spin rotator through a feedback loop in a storage ring

JuSER Publikationsportal
Particle Accelerators and Free-Electron Lasers
article

Maintaining a resonance condition of an rf spin rotator through a feedback loop in a storage ring

article en

Abstract

This paper presents the successful application of a phase-lock feedback system to maintain the resonance condition of a radio frequency (rf) spin rotator (specifically, an rf Wien filter) with respect to a 120 kHz spin precession in the Cooler Synchrotron (COSY) storage ring. Real-time monitoring of the spin precession and the rf Wien filter signal allows the relative phase between the two to be stabilized at an arbitrary setpoint. The feedback system compensates for deviations in the relative phase by adjusting the frequency and/or phase of the rf device as needed. With this method, a variation in the phase relative to the demanded value with a standard deviation of 𝜎Δ⁢𝜑≈0.2 rad could be achieved. The system was implemented in two runs aiming at a first direct measurement of the deuteron electric dipole moment in 2018 and 2021. In addition, the difference between a single-bunch beam affected by the spin rotator and a two-bunch system in which only one bunch is exposed to the spin rotator fields is discussed. Both methods have been used during these beam times. The ability to keep the spin precession and the rf fields synchronized is crucial for future investigations of electric dipole moments of charged particles using storage rings.

JuSER Publikationsportal
Forschungszentrum Jülich (DE)
Affordable and clean energy
Openalex Percentile: Top 58%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Maintaining a resonance condition of an rf spin rotator through a feedback loop in a storage ring · JuSER Publikationsportal (2025) | TGRS Research Map | TGRS