Effect of Superficially Porous Particles on Chromatographic Analysis Time of Flavonoids

Due to superficial particles and remarkable packing technologies, the HALO-HILIC column outperformed regular porous columns in terms of analysis time. This study analyzes and identifies kaempferol and luteolin flavonoids in natural herbs. A fast, novel chromatographic method combining superficially porous silica particles packed in a column served as the separation tool for hydrophilic interaction liquid chromatography coupled with a UV detection system is being introduced in this work. Flavonoid separation and quantification took six minutes using only superficial porous particles in the HILIC column compared to hours using fully porous particles in the RP columns. The findings demonstrated that the HILIC mode might be utilized to determine kaempferol and luteolin levels in ginkgo plant samples. A commercial HALO-HILIC column was used to create the calibration curve, which had the following specifications: linear range (0.065-35 µgmL-1 for kaempferol and 0.065-9 µgmL-1 for luteolin), RSD% not exceeding 0.54%, the limit of quantification (0.036 µgmL-1 for kaempferol and 0.024 µgmL-1 for luteolin), and limit of determination (0.012 µgmL-1 for kaempferol and 0.008 µgmL-1 for luteolin).

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.30526/38.2.3639
Primary Topic
Chromatography in Natural Products
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Superficially Porous Particles on Chromatographic Analysis Time of Flavonoids

SHILAP Revista de lepidopterología
Chromatography in Natural Products
article

Effect of Superficially Porous Particles on Chromatographic Analysis Time of Flavonoids

article en

Abstract

Due to superficial particles and remarkable packing technologies, the HALO-HILIC column outperformed regular porous columns in terms of analysis time. This study analyzes and identifies kaempferol and luteolin flavonoids in natural herbs. A fast, novel chromatographic method combining superficially porous silica particles packed in a column served as the separation tool for hydrophilic interaction liquid chromatography coupled with a UV detection system is being introduced in this work. Flavonoid separation and quantification took six minutes using only superficial porous particles in the HILIC column compared to hours using fully porous particles in the RP columns. The findings demonstrated that the HILIC mode might be utilized to determine kaempferol and luteolin levels in ginkgo plant samples. A commercial HALO-HILIC column was used to create the calibration curve, which had the following specifications: linear range (0.065-35 µgmL-1 for kaempferol and 0.065-9 µgmL-1 for luteolin), RSD% not exceeding 0.54%, the limit of quantification (0.036 µgmL-1 for kaempferol and 0.024 µgmL-1 for luteolin), and limit of determination (0.012 µgmL-1 for kaempferol and 0.008 µgmL-1 for luteolin).

SHILAP Revista de lepidopterología
University of Baghdad (IQ)
Openalex Percentile: Top 56%
Chromatography in Natural Products
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.