Force Myography Sensors for Gait Phase Detection

In human-machine interaction, muscle activity serves as an indicator of the human motion intent and is mostly assessed using electromyography (EMG). EMG requires special skin preparation, accurate electrode placement, and is affected by sweating. In contrast, force myography (FMG) measures the mechanical muscle contraction, thereby promising reliable longterm acquisition for gait phase detection. With one individual piezoelectric sensor patch per muscle, reduced cross-talk around the limb circumference is expected compared to state-of-theart elastic straps comprising several sensors linked together. In this work, seven physically unimpaired participants wore four 3D-printed, highly sensitive ferroelectret sensors along with four EMG electrodes on the lower limbs while walking on an instrumented treadmill at normal walking speed. Tibialis anterior (TA) and vastus medialis (VM) are best suited for heel strike and toe-off detection with the FMG sensors to discriminate between swing and stance phases. The signal variability across all strides is exceptionally low. The characteristic FMG peaks differ from the ground reaction force reference by 3.6% ± 2.0% of the stride time for TA and 1.2% ± 1.2% for VM. Using the customizable ferroelectret sensors, this FMG system provides a substitute or supplement in sensor fusion for conventional EMG.

Publication Details

Journal
TUbilio (Technical University of Darmstadt)
Published
2025-01-01
DOI
https://doi.org/10.26083/tuprints-00029906
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Force Myography Sensors for Gait Phase Detection

TUbilio (Technical University of Darmstadt)
Muscle activation and electromyography studies
article

Force Myography Sensors for Gait Phase Detection

article en

Abstract

In human-machine interaction, muscle activity serves as an indicator of the human motion intent and is mostly assessed using electromyography (EMG). EMG requires special skin preparation, accurate electrode placement, and is affected by sweating. In contrast, force myography (FMG) measures the mechanical muscle contraction, thereby promising reliable longterm acquisition for gait phase detection. With one individual piezoelectric sensor patch per muscle, reduced cross-talk around the limb circumference is expected compared to state-of-theart elastic straps comprising several sensors linked together. In this work, seven physically unimpaired participants wore four 3D-printed, highly sensitive ferroelectret sensors along with four EMG electrodes on the lower limbs while walking on an instrumented treadmill at normal walking speed. Tibialis anterior (TA) and vastus medialis (VM) are best suited for heel strike and toe-off detection with the FMG sensors to discriminate between swing and stance phases. The signal variability across all strides is exceptionally low. The characteristic FMG peaks differ from the ground reaction force reference by 3.6% ± 2.0% of the stride time for TA and 1.2% ± 1.2% for VM. Using the customizable ferroelectret sensors, this FMG system provides a substitute or supplement in sensor fusion for conventional EMG.

TUbilio (Technical University of Darmstadt)
Reduced inequalities, Peace, Justice and strong institutions
Openalex Percentile: Top 59%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.