Design of Glued-in-rods connections in timber structures

Timber structures in glulam are booming in recent years. It has led to the development of high-performance connections, like glued-in-rods (GiR). Glued-in-rods are threaded rods inserted into boreholes with glue. They offer aesthetic advantages, high performance and stiffness. Lack of knowledge about this connection, whose design is not governed by the Eurocode, considerably limits their use. This study presents experimental testing on glulam beam-to-column connections using glued-in-rods and a traditional connection (metal clamp). Two configurations of GiR connection are tested, one with 2 rods, and one with 4 rods. Experimental tests show that glued-in-rods connections have greater rotational stiffness than the traditional connection. The observed failure modes of the connections were the yielding rods by tensile force. It was also concluded that capacity appears to be a function of the number of rods: doubling the number of rods doubles the capacity of the connection (rods on the same axis). The same applies to rotational stiffness. Comparison of experimental results with model predictions showed good agreement, with a deviation under 15% for the maximum tension experienced in the rods.

Publication Details

Journal
Association Universitaire de Génie Civil
Published
2025-01-22
DOI
https://doi.org/10.26168/ajce.43.1.1
Primary Topic
Wood Treatment and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of Glued-in-rods connections in timber structures

Association Universitaire de Génie Civil
Wood Treatment and Properties
article

Design of Glued-in-rods connections in timber structures

article en

Abstract

Timber structures in glulam are booming in recent years. It has led to the development of high-performance connections, like glued-in-rods (GiR). Glued-in-rods are threaded rods inserted into boreholes with glue. They offer aesthetic advantages, high performance and stiffness. Lack of knowledge about this connection, whose design is not governed by the Eurocode, considerably limits their use. This study presents experimental testing on glulam beam-to-column connections using glued-in-rods and a traditional connection (metal clamp). Two configurations of GiR connection are tested, one with 2 rods, and one with 4 rods. Experimental tests show that glued-in-rods connections have greater rotational stiffness than the traditional connection. The observed failure modes of the connections were the yielding rods by tensile force. It was also concluded that capacity appears to be a function of the number of rods: doubling the number of rods doubles the capacity of the connection (rods on the same axis). The same applies to rotational stiffness. Comparison of experimental results with model predictions showed good agreement, with a deviation under 15% for the maximum tension experienced in the rods.

Association Universitaire de Génie Civil
Sustainable cities and communities
Openalex Percentile: Top 55%
Wood Treatment and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.