Intracoronary ECG ST-segment shift remission time during reactive myocardial hyperemia. A new method to assess hemodynamic coronary stenosis severity

Fractional flow reserve (FFR) measurements are recommended for assessing hemodynamic coronary stenosis severity. Intracoronary ECG (icECG) is easily obtainable and highly sensitive in detecting myocardial ischemia due to its close vicinity to the myocardium. We hypothesized that the remission time of myocardial ischemia on icECG after a controlled coronary occlusion accurately detects hemodynamically relevant coronary stenosis. This retrospective, observational study included patients with chronic coronary syndrome undergoing hemodynamic coronary stenosis assessment immediately following a strictly 1-min proximal coronary artery balloon occlusion with simultaneous icECG recording. icECG was used for a beat-to-beat analysis of the ST-segment shift during reactive hyperemia immediately following balloon deflation. The time from coronary balloon deflation until the ST-segment shift reached 37% of its maximum level, i.e., icECG ST-segment shift remission time (τ-icECG in seconds), was obtained by an automatic algorithm. τ-icECG was tested against the simultaneously obtained reactive hyperemia FFR at a threshold of 0.80 as a reference parameter. From 120 patients, 139 icECGs (age, 68 ± 10 yr old) were analyzed. Receiver operating characteristic (ROC) analysis of τ-icECG for the detection of hemodynamically relevant coronary stenosis at an FFR of ≤0.80 was performed. The area under the ROC curve was equal to 0.621 (P = 0.0363) at an optimal τ-icECG threshold of 8 s (sensitivity, 61%; specificity, 67%). τ-icECG correlated inversely and linearly with FFR (P = 0.0327). This first proof-of-concept study demonstrates that τ-icECG, a measure of icECG ST segment-shift remission after a 1-min coronary artery balloon occlusion accurately detects hemodynamically relevant coronary artery stenosis according to FFR at a threshold of ≥8 s.

Publication Details

Journal
Institutional Repository (IHS Vienna)
Published
2024-10-01
DOI
https://doi.org/10.26041/fhnw-11852
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intracoronary ECG ST-segment shift remission time during reactive myocardial hyperemia. A new method to assess hemodynamic coronary stenosis severity

Institutional Repository (IHS Vienna)
Coronary Interventions and Diagnostics
article

Intracoronary ECG ST-segment shift remission time during reactive myocardial hyperemia. A new method to assess hemodynamic coronary stenosis severity

article en

Abstract

Fractional flow reserve (FFR) measurements are recommended for assessing hemodynamic coronary stenosis severity. Intracoronary ECG (icECG) is easily obtainable and highly sensitive in detecting myocardial ischemia due to its close vicinity to the myocardium. We hypothesized that the remission time of myocardial ischemia on icECG after a controlled coronary occlusion accurately detects hemodynamically relevant coronary stenosis. This retrospective, observational study included patients with chronic coronary syndrome undergoing hemodynamic coronary stenosis assessment immediately following a strictly 1-min proximal coronary artery balloon occlusion with simultaneous icECG recording. icECG was used for a beat-to-beat analysis of the ST-segment shift during reactive hyperemia immediately following balloon deflation. The time from coronary balloon deflation until the ST-segment shift reached 37% of its maximum level, i.e., icECG ST-segment shift remission time (τ-icECG in seconds), was obtained by an automatic algorithm. τ-icECG was tested against the simultaneously obtained reactive hyperemia FFR at a threshold of 0.80 as a reference parameter. From 120 patients, 139 icECGs (age, 68 ± 10 yr old) were analyzed. Receiver operating characteristic (ROC) analysis of τ-icECG for the detection of hemodynamically relevant coronary stenosis at an FFR of ≤0.80 was performed. The area under the ROC curve was equal to 0.621 (P = 0.0363) at an optimal τ-icECG threshold of 8 s (sensitivity, 61%; specificity, 67%). τ-icECG correlated inversely and linearly with FFR (P = 0.0327). This first proof-of-concept study demonstrates that τ-icECG, a measure of icECG ST segment-shift remission after a 1-min coronary artery balloon occlusion accurately detects hemodynamically relevant coronary artery stenosis according to FFR at a threshold of ≥8 s.

Institutional Repository (IHS Vienna)
Good health and well-being
Openalex Percentile: Top 51%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.