Purpose: To evaluate the survival and success rates of a novel two-piece zirconia implant system restored with screw-retained glass–ceramic crowns over 12 months, including assessment of bone levels, soft tissue parameters, and patient-reported outcome measures. Methods: Twenty-four patients received single two-piece zirconia implants (CERALOG® Hexalobe) in healed sites. After a 6-month healing period, implants received provisional screw-retained crowns on PEKK temporary abutments, followed by definitive lithium disilicate crowns (IPS e.max Press) on PEKK abutments. Clinical and radiographic examinations were performed at implant placement, re-entry, definitive loading, and 12-month follow-up, along with patient-reported outcome measures. Results: The implant survival rate at 12 months was 60.9%. Nine implants were lost: two due to lack of osseointegration at re-entry, four due to mobility after loading, and three due to fractures in the coronal third after loading. Surviving implants showed stable soft tissue parameters with mean probing pocket depths of 2.7 ± 0.7 mm at 12 months. The mean distance from implant shoulder to first bone contact decreased from 1.9 ± 0.6 mm at loading to 1.4 ± 0.6 mm at 12 months. Patients with surviving implants reported high satisfaction scores (4.8 ± 0.4) for function and aesthetics. Conclusions: The two-piece zirconia implant system with screw-retained restorations showed unsatisfactory survival rates. The combination of ceramic implants with screw-retained prosthetic restorations may have contributed to the higher failure rates observed. As a pilot study with a relatively small sample size, these findings should be confirmed by larger multicenter studies to validate these preliminary results.

Publication Details

Journal
Digitalen Hochschulbibliothek Sachsen-Anhalt (Universitäts- und Landesbibliothek Sachsen-Anhalt)
Published
2025-01-01
DOI
https://doi.org/10.25673/119123
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prospective clinical study to evaluate the success and survival of two-piece zirconia implants : a single-center study. 12-month results

Digitalen Hochschulbibliothek Sachsen-Anhalt (Universitäts- und Landesbibliothek Sachsen-Anhalt)
Dental Implant Techniques and Outcomes
article

Prospective clinical study to evaluate the success and survival of two-piece zirconia implants : a single-center study. 12-month results

article en

Abstract

Purpose: To evaluate the survival and success rates of a novel two-piece zirconia implant system restored with screw-retained glass–ceramic crowns over 12 months, including assessment of bone levels, soft tissue parameters, and patient-reported outcome measures. Methods: Twenty-four patients received single two-piece zirconia implants (CERALOG® Hexalobe) in healed sites. After a 6-month healing period, implants received provisional screw-retained crowns on PEKK temporary abutments, followed by definitive lithium disilicate crowns (IPS e.max Press) on PEKK abutments. Clinical and radiographic examinations were performed at implant placement, re-entry, definitive loading, and 12-month follow-up, along with patient-reported outcome measures. Results: The implant survival rate at 12 months was 60.9%. Nine implants were lost: two due to lack of osseointegration at re-entry, four due to mobility after loading, and three due to fractures in the coronal third after loading. Surviving implants showed stable soft tissue parameters with mean probing pocket depths of 2.7 ± 0.7 mm at 12 months. The mean distance from implant shoulder to first bone contact decreased from 1.9 ± 0.6 mm at loading to 1.4 ± 0.6 mm at 12 months. Patients with surviving implants reported high satisfaction scores (4.8 ± 0.4) for function and aesthetics. Conclusions: The two-piece zirconia implant system with screw-retained restorations showed unsatisfactory survival rates. The combination of ceramic implants with screw-retained prosthetic restorations may have contributed to the higher failure rates observed. As a pilot study with a relatively small sample size, these findings should be confirmed by larger multicenter studies to validate these preliminary results.

Digitalen Hochschulbibliothek Sachsen-Anhalt (Universitäts- und Landesbibliothek Sachsen-Anhalt)
Sustainable cities and communities
Openalex Percentile: Top 43%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.