Wearable upper arm SpO2 sensor for wellness monitoring

Objective: This paper describes the full development of a sensor for measuring optical heart rate (OHR) and blood oxygen saturation (SpO2). Methods: A wearable sensor with a new type of skin compatible dispensed lens was designed and manufactured. All critical optical components, light emitting diodes (LEDs) and photodiode (PD) were close to skin and gave maximum light intensity due to minimal loss in the lens structure. Lens and optical components formed a thin monolithic structure. Results: Suppressed crosstalk between LED and PD was achieved by using two types of dispensed material: light blocking and transparent. High signal to noise ratio (SNR) and amplitude in the alternating current (AC) part of the photoplethysmography (PPG) signal were achieved. User comfort was achieved by having a small sensor located on the upper arm. When re-training the algorithm from our first iteration, the multiwavelength PPG sensor showed an SpO2 RMSE of 2.61% with a 7-second average analysis for 25 participants. The average RMSE of heart rate over all 25 participants was 1.6 ± 1.1%. Conclusion: This study demonstrates a sensor with a clinical grade SpO2 measurement and a highly accurate OHR measurement that is also comfortable and easy to wear. Significance: A dispensing method provides a new way of manufacturing sensor elements for wearable sensors with increased performance with reduced crosstalk.

Publication Details

Journal
VIUspace
Published
2025-05-01
DOI
https://doi.org/10.25316/ir-20387
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable upper arm SpO2 sensor for wellness monitoring

VIUspace
Non-Invasive Vital Sign Monitoring
article

Wearable upper arm SpO2 sensor for wellness monitoring

article en

Abstract

Objective: This paper describes the full development of a sensor for measuring optical heart rate (OHR) and blood oxygen saturation (SpO2). Methods: A wearable sensor with a new type of skin compatible dispensed lens was designed and manufactured. All critical optical components, light emitting diodes (LEDs) and photodiode (PD) were close to skin and gave maximum light intensity due to minimal loss in the lens structure. Lens and optical components formed a thin monolithic structure. Results: Suppressed crosstalk between LED and PD was achieved by using two types of dispensed material: light blocking and transparent. High signal to noise ratio (SNR) and amplitude in the alternating current (AC) part of the photoplethysmography (PPG) signal were achieved. User comfort was achieved by having a small sensor located on the upper arm. When re-training the algorithm from our first iteration, the multiwavelength PPG sensor showed an SpO2 RMSE of 2.61% with a 7-second average analysis for 25 participants. The average RMSE of heart rate over all 25 participants was 1.6 ± 1.1%. Conclusion: This study demonstrates a sensor with a clinical grade SpO2 measurement and a highly accurate OHR measurement that is also comfortable and easy to wear. Significance: A dispensing method provides a new way of manufacturing sensor elements for wearable sensors with increased performance with reduced crosstalk.

VIUspace
Openalex Percentile: Top 59%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.