The Measurement of Neutron Contamination in High Energy X-Ray Radiotherapy Using a He-3 Gas Dosimeter

Introduction: Neutron contamination is likely caused by the collision of high-energy photon interactions (γ, ṉ) with heavy metals used in the construction of the accelerator. This study is essential to quantify the excess dose from neutron contamination by Elekta Precis. The main object is to assess the neutron contamination with a gas dosimeter containing He-3. Material and Methods: In this study, neutron contamination was estimated at different points in and out of the treatment room. We used two types of dosimeters: a He-3 gas dosimeter (CRAMAL 31) as a neutron dosimeter and Farmer ionization chambers, and PC-electrometer (Sun Nuclear, USA) which is sensitive to photons measured photo-neutron doses. Both the neutron and Farmer dosimeters were applied in the presence and absence of acrylic plates at the same point. In this study, Monte Carlo (MC) code was utilized to prepare the correct proportion of neutron dose. Results: At different points in and out of the treatment room, neutron contamination was approximately in the range of background dose (D = 0.001 µSv). The neutron dosimeter displayed 48.792 µSv, 25.456 µSv and 28.756 µSv for 6, 10 and 15 MV photon energy, respectively. He-3 gas dosimeter showed that the neutron dose net was negligible under the treatment field. Conclusion: He-3 gas dosimeter detected more than the usual neutron dose in 6 MV photon energy than we expected. Due to the high photon flux under the radiation fields, a He-3 neutron dosimeter reported photo-neutron dose. Nevertheless, the photo-neutron dose was in the range of micro Sievert (µSv). He-3 gas dosimeter was not suitable for neutron dosimetry in places with high photon fluence because of the low energy peak in the detection of neutrons.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.22038/ijmp.2024.75447.2332
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Measurement of Neutron Contamination in High Energy X-Ray Radiotherapy Using a He-3 Gas Dosimeter

SHILAP Revista de lepidopterología
Advanced Radiotherapy Techniques
article

The Measurement of Neutron Contamination in High Energy X-Ray Radiotherapy Using a He-3 Gas Dosimeter

article en

Abstract

Introduction: Neutron contamination is likely caused by the collision of high-energy photon interactions (γ, ṉ) with heavy metals used in the construction of the accelerator. This study is essential to quantify the excess dose from neutron contamination by Elekta Precis. The main object is to assess the neutron contamination with a gas dosimeter containing He-3. Material and Methods: In this study, neutron contamination was estimated at different points in and out of the treatment room. We used two types of dosimeters: a He-3 gas dosimeter (CRAMAL 31) as a neutron dosimeter and Farmer ionization chambers, and PC-electrometer (Sun Nuclear, USA) which is sensitive to photons measured photo-neutron doses. Both the neutron and Farmer dosimeters were applied in the presence and absence of acrylic plates at the same point. In this study, Monte Carlo (MC) code was utilized to prepare the correct proportion of neutron dose. Results: At different points in and out of the treatment room, neutron contamination was approximately in the range of background dose (D = 0.001 µSv). The neutron dosimeter displayed 48.792 µSv, 25.456 µSv and 28.756 µSv for 6, 10 and 15 MV photon energy, respectively. He-3 gas dosimeter showed that the neutron dose net was negligible under the treatment field. Conclusion: He-3 gas dosimeter detected more than the usual neutron dose in 6 MV photon energy than we expected. Due to the high photon flux under the radiation fields, a He-3 neutron dosimeter reported photo-neutron dose. Nevertheless, the photo-neutron dose was in the range of micro Sievert (µSv). He-3 gas dosimeter was not suitable for neutron dosimetry in places with high photon fluence because of the low energy peak in the detection of neutrons.

SHILAP Revista de lepidopterología
University of Neyshabur (IR), Gonabad University of Medical Sciences (IR), Imam Reza Hospital (IR), Sabzevar University of Medical Sciences (IR)
Openalex Percentile: Top 63%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.