Fabrication of a fast response non-enzymatic glucose sensor based on in-situ synthesized Cu-metal organic frameworks integrated with electrochemically reduced graphene quantum dots

Objective(s): During this study, a novel and fast response platform based on in-situ synthesis of Cu-metal organic frameworks (Cu-MOFs) integrated with electrochemically reduced graphene quantum dots (ErGQDs) was developed through an electrochemical deposition method and a conversation process for non-enzymatic glucose determination.Materials and Methods: In the first step, metallic copper and ErGQDs were simultaneous electrochemically deposited on the surface of carbon ceramic electrode (CCE). Then, metallic copper was converted to copper oxide by cyclic voltammetry technique. Finally, by adding the benzene-1, 3, 5-tricarboxylic acid (BTC), copper-based MOFs was formed on the surface of constructed electrode by an in-situ conversation process and the fabricated electrode (Cu-MOFs/ErGQDs/CCE) was used for the non-enzymatic electrochemical detection of glucose. The physicochemical characterization and electrocatalytic behavior of fabricated electrode toward glucose oxidation were studied through the suitable techniques. Results: The electrochemical results demonstrated that the Cu-MOFs/ErGQDs/CCE is a suitable sensor for glucose determination which exhibits wide linear ranges (2.0-500.0 µM), low detection limit [0.59 µM (S/N=3)], high sensitivity (5069 μA mM-1cm-2), stability (RSD%=3.02), reproducibility (RSD%= 2.09) and good selectivity. Conclusion: Overall, this study highlights the development of Cu-MOFs/ErGQDs/CCE as a sensor with promising characteristics for non-enzymatic determination of glucose. So that, the present sensor was used for detection of glucose in human blood serum and saliva samples.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-01-01
DOI
https://doi.org/10.22038/nmj.2024.75527.1833
Citations
2
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication of a fast response non-enzymatic glucose sensor based on in-situ synthesized Cu-metal organic frameworks integrated with electrochemically reduced graphene quantum dots

2 citations
SHILAP Revista de lepidopterología
Electrochemical sensors and biosensors
1.46
article

Fabrication of a fast response non-enzymatic glucose sensor based on in-situ synthesized Cu-metal organic frameworks integrated with electrochemically reduced graphene quantum dots

article en
2 citations

Abstract

Objective(s): During this study, a novel and fast response platform based on in-situ synthesis of Cu-metal organic frameworks (Cu-MOFs) integrated with electrochemically reduced graphene quantum dots (ErGQDs) was developed through an electrochemical deposition method and a conversation process for non-enzymatic glucose determination.Materials and Methods: In the first step, metallic copper and ErGQDs were simultaneous electrochemically deposited on the surface of carbon ceramic electrode (CCE). Then, metallic copper was converted to copper oxide by cyclic voltammetry technique. Finally, by adding the benzene-1, 3, 5-tricarboxylic acid (BTC), copper-based MOFs was formed on the surface of constructed electrode by an in-situ conversation process and the fabricated electrode (Cu-MOFs/ErGQDs/CCE) was used for the non-enzymatic electrochemical detection of glucose. The physicochemical characterization and electrocatalytic behavior of fabricated electrode toward glucose oxidation were studied through the suitable techniques. Results: The electrochemical results demonstrated that the Cu-MOFs/ErGQDs/CCE is a suitable sensor for glucose determination which exhibits wide linear ranges (2.0-500.0 µM), low detection limit [0.59 µM (S/N=3)], high sensitivity (5069 μA mM-1cm-2), stability (RSD%=3.02), reproducibility (RSD%= 2.09) and good selectivity. Conclusion: Overall, this study highlights the development of Cu-MOFs/ErGQDs/CCE as a sensor with promising characteristics for non-enzymatic determination of glucose. So that, the present sensor was used for detection of glucose in human blood serum and saliva samples.

SHILAP Revista de lepidopterología
Azarbaijan Shahid Madani University (IR)
Openalex Percentile: Top 14%
Electrochemical sensors and biosensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fabrication of a fast response non-enzymatic glucose sensor based on in-situ synthesized Cu-metal organic frameworks integrated with electrochemically reduced graphene quantum dots · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS