Direct comparison of pulse-driven and programmable AC Josephson voltage standards

The pulse-driven AC Josephson voltage standard (ACJVS) uses high-speed pulse sequences to drive a Josephson junction array, offering advantages such as spectral purity and wide bandwidth. The programmable Josephson voltage standard (PJVS), driven by a bias current, provides higher output amplitude but lower synthesis frequencies and higher-order harmonics. This paper presents a comparison of two AC quantum voltage systems using differential sampling techniques. The experiment verifies the consistency of AC quantum voltages at 50 Hz, 62.5 Hz, and 100 Hz under 0.75 V, and assesses the impact of sampler gain, frequency response, transmission line corrections, induced voltage, and crosstalk on the results. Comparison results indicate that the consistency between the two quantum voltage systems under the conditions of 50 Hz, 62.5 Hz, and 100 Hz frequencies with RMS amplitude of 0.75 V are (0.025±0.320) μV/V, (0.005±0.124) μV/V, and (0.150±0.215) μV/V, respectively. The research provide a technical foundation for the BIPM.EM-K10 comparison recommended by the International Bureau of Weights and Measures (BIPM).

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-01-01
DOI
https://doi.org/10.19753/j.issn1001-1390.2025.01.006
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct comparison of pulse-driven and programmable AC Josephson voltage standards

SHILAP Revista de lepidopterología
Advanced Electrical Measurement Techniques
article

Direct comparison of pulse-driven and programmable AC Josephson voltage standards

article en

Abstract

The pulse-driven AC Josephson voltage standard (ACJVS) uses high-speed pulse sequences to drive a Josephson junction array, offering advantages such as spectral purity and wide bandwidth. The programmable Josephson voltage standard (PJVS), driven by a bias current, provides higher output amplitude but lower synthesis frequencies and higher-order harmonics. This paper presents a comparison of two AC quantum voltage systems using differential sampling techniques. The experiment verifies the consistency of AC quantum voltages at 50 Hz, 62.5 Hz, and 100 Hz under 0.75 V, and assesses the impact of sampler gain, frequency response, transmission line corrections, induced voltage, and crosstalk on the results. Comparison results indicate that the consistency between the two quantum voltage systems under the conditions of 50 Hz, 62.5 Hz, and 100 Hz frequencies with RMS amplitude of 0.75 V are (0.025±0.320) μV/V, (0.005±0.124) μV/V, and (0.150±0.215) μV/V, respectively. The research provide a technical foundation for the BIPM.EM-K10 comparison recommended by the International Bureau of Weights and Measures (BIPM).

SHILAP Revista de lepidopterología
National Institute of Metrology (CN), China Jiliang University (CN)
Affordable and clean energy
Openalex Percentile: Top 58%
Advanced Electrical Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Direct comparison of pulse-driven and programmable AC Josephson voltage standards · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS