Structural fault analysis of air-core reactors under lightning impulse

In ultra-high voltage (UHV) converter stations, the encapsulation of air-core reactors may deform under lightning impulse due to electromagnetic forces, which may induce structural faults and jeopardize the safe operation of power system. To address this challenge, an electromagnetic-mechanical stress coupling simulation model is established for air-core reactors. The influence of parameters such as current peak and rise time in lightning current mathematical models on the reactor’s electromagnetic distribution and structural deformation is analyzed. Based on the probabilistic characteristics of lightning impulse, a Bayesian network-based method is proposed for fault cause analysis. This method utilizes Bayesian network to compute prior and posterior probabilities, enabling systematic fault diagnosis through forward reasoning and backward inference.The results indicate that the lightning current amplitude, combined with its rate of rise (RoR), exhibits a strong correlation with structural faults in reactor encapsulations, making it a critical factor in such failures. A field case study from an actual converter station corroborates the validity and practical applicability of the proposed simulation model and analytical approach.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
DOI
https://doi.org/10.19585/j.zjdl.202505013
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural fault analysis of air-core reactors under lightning impulse

SHILAP Revista de lepidopterología
Lightning and Electromagnetic Phenomena
article

Structural fault analysis of air-core reactors under lightning impulse

article en

Abstract

In ultra-high voltage (UHV) converter stations, the encapsulation of air-core reactors may deform under lightning impulse due to electromagnetic forces, which may induce structural faults and jeopardize the safe operation of power system. To address this challenge, an electromagnetic-mechanical stress coupling simulation model is established for air-core reactors. The influence of parameters such as current peak and rise time in lightning current mathematical models on the reactor’s electromagnetic distribution and structural deformation is analyzed. Based on the probabilistic characteristics of lightning impulse, a Bayesian network-based method is proposed for fault cause analysis. This method utilizes Bayesian network to compute prior and posterior probabilities, enabling systematic fault diagnosis through forward reasoning and backward inference.The results indicate that the lightning current amplitude, combined with its rate of rise (RoR), exhibits a strong correlation with structural faults in reactor encapsulations, making it a critical factor in such failures. A field case study from an actual converter station corroborates the validity and practical applicability of the proposed simulation model and analytical approach.

SHILAP Revista de lepidopterología
Shanghai Electric (China) (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 70%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.