Harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farms

As the rectification-side devices of the offshore wind power transmission systems, the diode uncontrolled rectification units are a technological hotspot in the offshore wind power sector. Multiplex rectifier circuits are usually employed for diode uncontrolled rectification, with a 12-pulse rectifier circuits being the most common. Theoretical analyses of serial and parallel multiplex wiring in the 12-pulse and the 24-pulse rectifier circuits within the multiplex rectifier circuits have been conducted. This entails studying the harmonic characteristics of the alternating current on the AC side and the voltage on the DC side, deriving the calculation methods for the harmonic numbers and the harmonic amplitudes, and determining the total current harmonic distortion rate and the voltage ripple factor. Comparative analyses are made on the characteristics of 12-pulse and 24-pulse rectifier circuits, investigating the feasibility of applying the 24-pulse rectifier circuits in the diode uncontrolled rectification units. Simulations are carried out on the PSCAD/EMTDC platform.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-11-01
DOI
https://doi.org/10.19585/j.zjdl.202411003
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farms

1 citations
SHILAP Revista de lepidopterología
HVDC Systems and Fault Protection
0.21
article

Harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farms

article en
1 citations

Abstract

As the rectification-side devices of the offshore wind power transmission systems, the diode uncontrolled rectification units are a technological hotspot in the offshore wind power sector. Multiplex rectifier circuits are usually employed for diode uncontrolled rectification, with a 12-pulse rectifier circuits being the most common. Theoretical analyses of serial and parallel multiplex wiring in the 12-pulse and the 24-pulse rectifier circuits within the multiplex rectifier circuits have been conducted. This entails studying the harmonic characteristics of the alternating current on the AC side and the voltage on the DC side, deriving the calculation methods for the harmonic numbers and the harmonic amplitudes, and determining the total current harmonic distortion rate and the voltage ripple factor. Comparative analyses are made on the characteristics of 12-pulse and 24-pulse rectifier circuits, investigating the feasibility of applying the 24-pulse rectifier circuits in the diode uncontrolled rectification units. Simulations are carried out on the PSCAD/EMTDC platform.

SHILAP Revista de lepidopterología
Affordable and clean energy
Openalex Percentile: Top 43%
HVDC Systems and Fault Protection
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farms · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS