Identification of Abnormal data in online dissolved gas monitoring in oil based on PCA and Fast-MCD

To detect the operational status of transformers by online monitoring of dissolved gases in oil is critical for ensuring its stable operation. However, faults in monitoring devices can result in abnormal data, severely impacting the effect of online monitoring. To address this issue, a method for identifying abnormal data in dissolved gas monitoring based on principal component analysis (PCA) and fast minimum covariance determinant (Fast-MCD) is proposed. First, the PCA is used to reduce the dimensionality of time-series data for dissolved gas in oil, effectively eliminating redundant features. Next, robust statistical theory is applied to the reduced data using Fast-MCD to identify anomalies. Finally, the identified anomalies are analyzed to determine the source of the fault. Case studies demonstrate that the proposed method effectively identifies faults in online dissolved gas monitoring devices, outperforming conventional methods with an accuracy of 99.1%.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.19585/j.zjdl.202503011
Primary Topic
Human Mobility and Location-Based Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identification of Abnormal data in online dissolved gas monitoring in oil based on PCA and Fast-MCD

SHILAP Revista de lepidopterología
Human Mobility and Location-Based Analysis
article

Identification of Abnormal data in online dissolved gas monitoring in oil based on PCA and Fast-MCD

article en

Abstract

To detect the operational status of transformers by online monitoring of dissolved gases in oil is critical for ensuring its stable operation. However, faults in monitoring devices can result in abnormal data, severely impacting the effect of online monitoring. To address this issue, a method for identifying abnormal data in dissolved gas monitoring based on principal component analysis (PCA) and fast minimum covariance determinant (Fast-MCD) is proposed. First, the PCA is used to reduce the dimensionality of time-series data for dissolved gas in oil, effectively eliminating redundant features. Next, robust statistical theory is applied to the reduced data using Fast-MCD to identify anomalies. Finally, the identified anomalies are analyzed to determine the source of the fault. Case studies demonstrate that the proposed method effectively identifies faults in online dissolved gas monitoring devices, outperforming conventional methods with an accuracy of 99.1%.

SHILAP Revista de lepidopterología
China Jiliang University (CN)
Openalex Percentile: Top 59%
Human Mobility and Location-Based Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Identification of Abnormal data in online dissolved gas monitoring in oil based on PCA and Fast-MCD · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS