GA-SVM method for single-phase grounding fault line selection in distribution network based on feature fusion

Aiming at the low accuracy of line selection method when the data amount of single-phase grounding fault in distribution network is small, a genetic algorithm optimized support vector machine (GA-SVM) method for single-phase grounding fault line selection in distribution network based on feature fusion is proposed, which adopts Fourier transform, the active power method and wavelet packet transform decompose the transient zero-sequence current of each line under different fault conditions, extracts four features, including fundamental wave amplitude, fifth harmonic amplitude, average active power component and wavelet energy value. The four features are fused by principal component analysis method, the principal component is extracted, and the feature database is established. 80% of the feature database is used as the training set, 20% as the test set, the samples in the feature database are trained by GA-SVM to realize fault line selection. The simulation model of distribution network with five feeders is built by MATLAB/Simulink. The results show that the proposed algorithm can realize fault line selection through small sample datawith high accuracy and strong applicability.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-01-01
DOI
https://doi.org/10.19753/j.issn1001-1390.2025.01.017
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GA-SVM method for single-phase grounding fault line selection in distribution network based on feature fusion

SHILAP Revista de lepidopterología
Power Systems Fault Detection
article

GA-SVM method for single-phase grounding fault line selection in distribution network based on feature fusion

article en

Abstract

Aiming at the low accuracy of line selection method when the data amount of single-phase grounding fault in distribution network is small, a genetic algorithm optimized support vector machine (GA-SVM) method for single-phase grounding fault line selection in distribution network based on feature fusion is proposed, which adopts Fourier transform, the active power method and wavelet packet transform decompose the transient zero-sequence current of each line under different fault conditions, extracts four features, including fundamental wave amplitude, fifth harmonic amplitude, average active power component and wavelet energy value. The four features are fused by principal component analysis method, the principal component is extracted, and the feature database is established. 80% of the feature database is used as the training set, 20% as the test set, the samples in the feature database are trained by GA-SVM to realize fault line selection. The simulation model of distribution network with five feeders is built by MATLAB/Simulink. The results show that the proposed algorithm can realize fault line selection through small sample datawith high accuracy and strong applicability.

SHILAP Revista de lepidopterología
North China University of Technology (CN), Shanxi Datong University (CN)
Affordable and clean energy
Openalex Percentile: Top 49%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

GA-SVM method for single-phase grounding fault line selection in distribution network based on feature fusion · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS