"Finite element analysis and validation of nuclear equipment personnel airlock sealing structure"

The Mooney-Rivlin model was used to perform finite element analysis of sealing structure of double-channel O-ring seal for personnel airlock in nuclear power plant, the von Mises stress and contact stress of the O-ring seal at different compression size were simulated, and the sealing performance was verified through a test stand. The results showed that the maximum contact stress between the O-ring and sealing groove was greater than the maximum von Mises stress at different compression size. The sea-ling effect could be achieved when the compression rate was greater than 2% (compression size 0.3 mm). However, the O-ring compression rate took compression size the value of 1.6 mm (compression rate 10.67%) after considering the manufacturing tole-rances and safety margins. The test of stand verified rationality and effectiveness of the double-channel O-ring sealing structure.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-01-01
DOI
https://doi.org/10.19908/j.cnki.issn1000-1255.2025.01.0065
Primary Topic
Mechanical stress and fatigue analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

"Finite element analysis and validation of nuclear equipment personnel airlock sealing structure"

SHILAP Revista de lepidopterología
Mechanical stress and fatigue analysis
article

"Finite element analysis and validation of nuclear equipment personnel airlock sealing structure"

article en

Abstract

The Mooney-Rivlin model was used to perform finite element analysis of sealing structure of double-channel O-ring seal for personnel airlock in nuclear power plant, the von Mises stress and contact stress of the O-ring seal at different compression size were simulated, and the sealing performance was verified through a test stand. The results showed that the maximum contact stress between the O-ring and sealing groove was greater than the maximum von Mises stress at different compression size. The sea-ling effect could be achieved when the compression rate was greater than 2% (compression size 0.3 mm). However, the O-ring compression rate took compression size the value of 1.6 mm (compression rate 10.67%) after considering the manufacturing tole-rances and safety margins. The test of stand verified rationality and effectiveness of the double-channel O-ring sealing structure.

SHILAP Revista de lepidopterología
SGIDI Engineering Consulting (China) (CN), Shanghai Architectural Design & Research Institute (CN)
Life below water
Openalex Percentile: Top 54%
Mechanical stress and fatigue analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

"Finite element analysis and validation of nuclear equipment personnel airlock sealing structure" · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS