The design and accurate calibration of HIAF-Ring BPM

Beam Position Monitors (BPM) are the non-destructive monitors used most frequently at nearly all linacs, cyclotrons, and synchrotrons. The most basic function of BPM is to provide the accurate position of the centre of mass of the beam for closed orbit feedback and other demands. However, due to the error of actual processing, the k value and the actual electric center will be different with the ideal k value and electric center of BPM, which requires us to accurately measure the k value and offset value of each set of BPM offline. There are 72 sets of BPMs in HIAF BRing & SRing, with 10 specifications and plate radius ranging from 180mm to 330mm, but the shape and size of the front and back pipes connected to bpms are variety during actual installation. Based on theoretical analysis, the k value and offset value of the BPM which electrode plates are too close to the flange are greatly affected by the pipes connected to bpm at both ends, and the measurement error can even reach 9mm. Therefore, this paper takes HIAF BRing and SRing BPM calibration as examples to explain how to accurately calibrate BPM.

Publication Details

Journal
JACOW
Published
2024-12-18
DOI
https://doi.org/10.18429/jacow-ibic2024-tup45
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The design and accurate calibration of HIAF-Ring BPM

JACOW
Particle accelerators and beam dynamics
article

The design and accurate calibration of HIAF-Ring BPM

article en

Abstract

Beam Position Monitors (BPM) are the non-destructive monitors used most frequently at nearly all linacs, cyclotrons, and synchrotrons. The most basic function of BPM is to provide the accurate position of the centre of mass of the beam for closed orbit feedback and other demands. However, due to the error of actual processing, the k value and the actual electric center will be different with the ideal k value and electric center of BPM, which requires us to accurately measure the k value and offset value of each set of BPM offline. There are 72 sets of BPMs in HIAF BRing & SRing, with 10 specifications and plate radius ranging from 180mm to 330mm, but the shape and size of the front and back pipes connected to bpms are variety during actual installation. Based on theoretical analysis, the k value and offset value of the BPM which electrode plates are too close to the flange are greatly affected by the pipes connected to bpm at both ends, and the measurement error can even reach 9mm. Therefore, this paper takes HIAF BRing and SRing BPM calibration as examples to explain how to accurately calibrate BPM.

JACOW
Affordable and clean energy
Openalex Percentile: Top 45%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.